Purpose: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%). heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95. P < 0.0001). Conclusion: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.

Multislice multiecho T2*cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload RID A-6953-2008

LANDINI, LUIGI;
2006-01-01

Abstract

Purpose: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%). heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95. P < 0.0001). Conclusion: Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.
2006
Pepe, A; Positano, V; Santarelli, Mf; Sorrentino, F; Cracolici, E; De Marchi, D; Maggio, A; Midiri, M; Landini, Luigi; Lombardi, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/102677
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 153
social impact