The evaluation of aortic valve calcium burden is important when planning for transcatheter aortic valve implantation (TAVI). Although a robust golden standard methodology is available for calcium evaluation on noncontrast-enhanced (NCE) computed tomographic (CT) series, a standard reference for calcium assessment on contrast-enhanced CT series is currently lacking.

Threshold for calcium volume evaluation in patients with aortic valve stenosis: correlation with Agatston score

Angelillis, Marco;Mochi, Veronica;Christou, Andrea;Spontoni, Paolo;De Carlo, Marco;Miccoli, Mario;Petronio, Anna S
2021-01-01

Abstract

The evaluation of aortic valve calcium burden is important when planning for transcatheter aortic valve implantation (TAVI). Although a robust golden standard methodology is available for calcium evaluation on noncontrast-enhanced (NCE) computed tomographic (CT) series, a standard reference for calcium assessment on contrast-enhanced CT series is currently lacking.
2021
Angelillis, Marco; Costa, Giulia; De Backer, Ole; Mochi, Veronica; Christou, Andrea; Giannini, Cristina; Spontoni, Paolo; De Carlo, Marco; Søndergaard, Lars; Miccoli, Mario; Petronio, Anna S
File in questo prodotto: