Results from the variable gravity pool boiling experiments performed during the 52nd ESA parabolic flight campaign are reported in this paper. During a typical parabola, the gravity acceleration changes from 1.8gE (high gravity) to ~0gE (low gravity) and finally back to 1.8gE. The two high gravity periods and the microgravity period are each roughly maintained for 20 seconds while the transition from high gravity to low gravity and vice versa occurs over a period of 3–5 seconds. Use of the high feedback frequency microheater array allowed quasi-steady boiling data over the continuous range of gravity levels (0gE-1.8gE). The experimental apparatus consisted of a boiling chamber with a 7×7 mm2 microheater array in a 10×10 configuration. Each heater in the array was individually controlled to maintain a constant temperature. The array could be operated in a full configuration or a selectively powered reduced set of 3×3 heaters. Experiments were performed with FC-72 as the test fluid, the pressure was maintained at a constant value between 1 and 1.13 atm and the subcooling ranged from 27 to 11 K. An external electric field was imposed over the boiling surface by means of a grid consisting of 4 rods, laid parallel to the surface; voltages up to 10 kV were applied. The electric field was effective in reducing the size of the detaching bubbles, and increasing the heat transfer compared to the values in low-g, although its effectiveness decayed as the heat flux/superheat increased. The current results compared well with previous results obtained in the ARIEL apparatus that was operated in orbital flight.

Boiling in variable gravity under the action of an electric field: results of parabolic flight experiments

DI MARCO, PAOLO;
2011-01-01

Abstract

Results from the variable gravity pool boiling experiments performed during the 52nd ESA parabolic flight campaign are reported in this paper. During a typical parabola, the gravity acceleration changes from 1.8gE (high gravity) to ~0gE (low gravity) and finally back to 1.8gE. The two high gravity periods and the microgravity period are each roughly maintained for 20 seconds while the transition from high gravity to low gravity and vice versa occurs over a period of 3–5 seconds. Use of the high feedback frequency microheater array allowed quasi-steady boiling data over the continuous range of gravity levels (0gE-1.8gE). The experimental apparatus consisted of a boiling chamber with a 7×7 mm2 microheater array in a 10×10 configuration. Each heater in the array was individually controlled to maintain a constant temperature. The array could be operated in a full configuration or a selectively powered reduced set of 3×3 heaters. Experiments were performed with FC-72 as the test fluid, the pressure was maintained at a constant value between 1 and 1.13 atm and the subcooling ranged from 27 to 11 K. An external electric field was imposed over the boiling surface by means of a grid consisting of 4 rods, laid parallel to the surface; voltages up to 10 kV were applied. The electric field was effective in reducing the size of the detaching bubbles, and increasing the heat transfer compared to the values in low-g, although its effectiveness decayed as the heat flux/superheat increased. The current results compared well with previous results obtained in the ARIEL apparatus that was operated in orbital flight.
2011
DI MARCO, Paolo; Raj, Rishi; Kim, Jungho
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/145586
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact