The present study deals with the application of high-performance-liquid-chromatography (HPLC) method for a quantitative detection of carnosine, anserine, L-histidine and 3-methyl-L-histidine in biological material with o-phthaldialdehyde (OPA) post column derivatisation at the constant temperature of 50 degrees C. For this purpose, some mobile-phases were prepared with scalar acetonitrile concentrations. A complete separation of all molecules, particularly for camosine and 3-methyl-L-histidine, was obtained with a solution of acetonitrile and 6mM hydrochloric acid with 0.48 M sodium chloride (5%:95% v/v). Post column derivatisation reaction at temperature of 50 degrees C permitted to obtain an increase in sensibility of all molecules. This method has been utilised for detection of histidine dipeptides in boar spermatozoa and in sheep milk. Concentrations (mean +/- S.E. nmol/10(9) spermatozoa) of carnosine (0.96 +/- 0.14) and anserine (0.83 +/- 0.18) in boar spermatozoa were significantly lower than those of L-histidine (52.85 +/- 4.86) and 3-methyl-L-histidine (83.07 +/- 7.1). Positive correlation was found between camosine and anserine contents (r=0.740; p < 0.01) and between L-histidine and 3-methyl-L-histidine (r=0.657; p < 0.01). All histidine dipeptides studied were also present in 40 samples of sheep milk. In a case of samples without unit-forming colonies (UFC) of Staphylococcus coagulase-positive, carnosine concentrations (9.17 +/- 0.89 nmol/ml) were higher than anserine (0.51 +/- 0.02 nmol/ml) and both were significantly lower in respect to L-histidine (49.51 +/- 6.48 nmol/ml) and 3-metyl-L-histidine (81.21 +/- 6.82 nmol/ml). A negative correlation was observed between carnosine milk levels (r=-0.773; p < 0.01) and UFC/ml of Staphylococcus coagulase-positive. In conclusion this very simple and fast method can be used to detect histidine dipeptides in biological compartments where their concentrations are very low.

Concentrations of carnosine, anserine, L-histidine and 3-methyl histidine in boar spermatozoa and sheep milk by a modified HPLC method RID C-9731-2009

DUCCI, MICHELE;NICCOLINI, ALBERTO;GAZZANO, ANGELO;CERRI, DOMENICO;SIGHIERI, CLAUDIO;MARTELLI, FRANCO
2006-01-01

Abstract

The present study deals with the application of high-performance-liquid-chromatography (HPLC) method for a quantitative detection of carnosine, anserine, L-histidine and 3-methyl-L-histidine in biological material with o-phthaldialdehyde (OPA) post column derivatisation at the constant temperature of 50 degrees C. For this purpose, some mobile-phases were prepared with scalar acetonitrile concentrations. A complete separation of all molecules, particularly for camosine and 3-methyl-L-histidine, was obtained with a solution of acetonitrile and 6mM hydrochloric acid with 0.48 M sodium chloride (5%:95% v/v). Post column derivatisation reaction at temperature of 50 degrees C permitted to obtain an increase in sensibility of all molecules. This method has been utilised for detection of histidine dipeptides in boar spermatozoa and in sheep milk. Concentrations (mean +/- S.E. nmol/10(9) spermatozoa) of carnosine (0.96 +/- 0.14) and anserine (0.83 +/- 0.18) in boar spermatozoa were significantly lower than those of L-histidine (52.85 +/- 4.86) and 3-methyl-L-histidine (83.07 +/- 7.1). Positive correlation was found between camosine and anserine contents (r=0.740; p < 0.01) and between L-histidine and 3-methyl-L-histidine (r=0.657; p < 0.01). All histidine dipeptides studied were also present in 40 samples of sheep milk. In a case of samples without unit-forming colonies (UFC) of Staphylococcus coagulase-positive, carnosine concentrations (9.17 +/- 0.89 nmol/ml) were higher than anserine (0.51 +/- 0.02 nmol/ml) and both were significantly lower in respect to L-histidine (49.51 +/- 6.48 nmol/ml) and 3-metyl-L-histidine (81.21 +/- 6.82 nmol/ml). A negative correlation was observed between carnosine milk levels (r=-0.773; p < 0.01) and UFC/ml of Staphylococcus coagulase-positive. In conclusion this very simple and fast method can be used to detect histidine dipeptides in biological compartments where their concentrations are very low.
2006
Ducci, Michele; Pacchini, S; Niccolini, Alberto; Gazzano, Angelo; Cerri, Domenico; Gadea, J; Bobowiec, R; Sighieri, Claudio; Martelli, Franco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/183132
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact