Abstract: The aim of the present study was to describe a 10 years single-centre experience in pacing and defibrillating leads removal using an effective and safe modified mechanical dilatation technique. We developed a single mechanical dilating sheath extraction technique with multiple venous entry site approaches. We performed a venous entry site approach (VEA) in cases of exposed leads and an alternative transvenous femoral approach (TFA) combined with an internal transjugular approach (ITA) in the presence of very tight binding sites causing failure of VEA extraction or in cases of free-floating leads. We attempted to remove 2062 leads [1825 pacing and 237 implantable cardiac defibrillating (ICD) leads; 1989 exposed at the venous entry site and 73 free-floating] in 1193 consecutive patients. The VEA was effective in 1799 leads, the TFA in 28, and the ITA in 205; in the overall population, we completely removed 2032 leads (98.4%), partially removed 18 (0.9%), and failed to remove 12 leads (0.6%). Major complications were observed in eight patients (0.7%), causing three deaths (0.3%). Mechanical single sheath extraction technique with multiple venous entry site approaches is effective, safe, and with a good cost effective profile for pacing and ICD leads removal.

Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads

BONGIORNI, MARIA GRAZIA;SEGRETI L;BALBARINI, ALBERTO;MARZILLI, MARIO;MARIANI, MARIO
2008-01-01

Abstract

Abstract: The aim of the present study was to describe a 10 years single-centre experience in pacing and defibrillating leads removal using an effective and safe modified mechanical dilatation technique. We developed a single mechanical dilating sheath extraction technique with multiple venous entry site approaches. We performed a venous entry site approach (VEA) in cases of exposed leads and an alternative transvenous femoral approach (TFA) combined with an internal transjugular approach (ITA) in the presence of very tight binding sites causing failure of VEA extraction or in cases of free-floating leads. We attempted to remove 2062 leads [1825 pacing and 237 implantable cardiac defibrillating (ICD) leads; 1989 exposed at the venous entry site and 73 free-floating] in 1193 consecutive patients. The VEA was effective in 1799 leads, the TFA in 28, and the ITA in 205; in the overall population, we completely removed 2032 leads (98.4%), partially removed 18 (0.9%), and failed to remove 12 leads (0.6%). Major complications were observed in eight patients (0.7%), causing three deaths (0.3%). Mechanical single sheath extraction technique with multiple venous entry site approaches is effective, safe, and with a good cost effective profile for pacing and ICD leads removal.
2008
Bongiorni, MARIA GRAZIA; Soldati, E; Zucchelli, G; DI CORI, A; Segreti, L; DE LUCIA, R; Solarino, G; Balbarini, Alberto; Marzilli, Mario; Mariani, Mario
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/200662
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 193
social impact