Background: the early diagnosis of non-palpable breast cancer is the object of recent developments in the imaging procedures employed for screening purposes. In some patients, the presence of microcalcifications (MC) is the only indication of tumor. Although X-ray mammography (MRx) has high sensitivity in detecting MC, its specificity is however too low for diagnostic purposes. The aim of this study was to compare 99mTc-sestamibi scintimammography (SMM) and MRx in the differential diagnosis between benign and malignant clusters of MC and to assess the possible incremental value of SMM on specificity. Material and Methods: A total of 283 consecutive women (mean age 53±8 years) with MC identified on X-ray mammograms underwent SMM. Scintigraphic images were acquired 10 minutes after the i.v. injection of 99mTc-sestamibi (740 MBq). Planar images of both breasts were simultaneously obtained in the lateral prone position and in the anterior and oblique projections using a dual head camera. Sixty-nine women underwent surgery, whereas the remaining 214 patients had completely negative follow-up for 5 years (a 5-year follow-up period is considered the “gold standard” for diagnosing benign lesions). Results: Histology demonstrated 32/69 primary breast carcinomas (prevalence of disease: 11% of all the 283 patients) and 37/69 benign lesions. The receveir operating characteristic (ROC) statistical technique was employed to compare the diagnostic value of Mrx alone to that of combined MRx and SMM. The detected difference between the areas under the MRx ROC curve (area=0.72, standard error 0.052) and the MRX and SMM ROC curve (area=0.86, standard error 0.039) was statistically significant (p<0.01). Moreover, the combination of MRx and SMM provided a significant improvement of the negative predictive value (NPV=98%) for MC with low-suspicion of malignancy at MRx. Conclusion: SMM can be considered as a complementary tool in the pre-operative work-up of patients with breast lesions. Furthermore, the high negative predictive value of this technique, makes it especially valuable in the perspective of reducing the number of negative breast biopsies or unnecessary surgical interventions.

Comparison between 99mTc-sestamibi scintimammography and X-ray mammography in the characterization of clusters of microcalcifications: a prospective long-term study

VOLTERRANI, DUCCIO;RONCELLA M;MARIANI, GIULIANO
2009-01-01

Abstract

Background: the early diagnosis of non-palpable breast cancer is the object of recent developments in the imaging procedures employed for screening purposes. In some patients, the presence of microcalcifications (MC) is the only indication of tumor. Although X-ray mammography (MRx) has high sensitivity in detecting MC, its specificity is however too low for diagnostic purposes. The aim of this study was to compare 99mTc-sestamibi scintimammography (SMM) and MRx in the differential diagnosis between benign and malignant clusters of MC and to assess the possible incremental value of SMM on specificity. Material and Methods: A total of 283 consecutive women (mean age 53±8 years) with MC identified on X-ray mammograms underwent SMM. Scintigraphic images were acquired 10 minutes after the i.v. injection of 99mTc-sestamibi (740 MBq). Planar images of both breasts were simultaneously obtained in the lateral prone position and in the anterior and oblique projections using a dual head camera. Sixty-nine women underwent surgery, whereas the remaining 214 patients had completely negative follow-up for 5 years (a 5-year follow-up period is considered the “gold standard” for diagnosing benign lesions). Results: Histology demonstrated 32/69 primary breast carcinomas (prevalence of disease: 11% of all the 283 patients) and 37/69 benign lesions. The receveir operating characteristic (ROC) statistical technique was employed to compare the diagnostic value of Mrx alone to that of combined MRx and SMM. The detected difference between the areas under the MRx ROC curve (area=0.72, standard error 0.052) and the MRX and SMM ROC curve (area=0.86, standard error 0.039) was statistically significant (p<0.01). Moreover, the combination of MRx and SMM provided a significant improvement of the negative predictive value (NPV=98%) for MC with low-suspicion of malignancy at MRx. Conclusion: SMM can be considered as a complementary tool in the pre-operative work-up of patients with breast lesions. Furthermore, the high negative predictive value of this technique, makes it especially valuable in the perspective of reducing the number of negative breast biopsies or unnecessary surgical interventions.
2009
Grosso, M; Chiacchio, S; Bianchi, F; Traino, C; Marini, C; Cilotti, A; Manca, G; Volterrani, Duccio; Roncella, M; Rampin, L; Marzola, Mc; Rubello, D; Mariani, Giuliano
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/204604
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact