In the direct use of geothermal energy without fluid extraction, heat transfer takes place with no alteration of the natural hydrogeological balance of the basin. An interesting solution both for thermal energy and power production could be the application of heat pipe principle, in particular the Closed Loop Two Phase Thermosyphons (CLTPT). In shallow or not much deep geothermal reservoirs with temperature below 100 C, the two phase closed loop thermosyphon can transfer heat very efficiently. In this case the most important task is the enhancement of the heat transfer mechanism between the heat exchanger and the aquifer. In the first part of the paper a review of particular applications connected to the geothermal heat pipe applications is proposed, then an analysis of the main technical elements regarding the geothermal aquifer exploitation through two phase thermosyphon systems are given. Some guidelines for power systems sizing are discussed and a proposal for the design of a single borehole heat extraction system with binary cycle utilization is provided.

On the use of heat pipe principle for the exploitation of medium –low temperature geothermal resources

FRANCO, ALESSANDRO;
2013-01-01

Abstract

In the direct use of geothermal energy without fluid extraction, heat transfer takes place with no alteration of the natural hydrogeological balance of the basin. An interesting solution both for thermal energy and power production could be the application of heat pipe principle, in particular the Closed Loop Two Phase Thermosyphons (CLTPT). In shallow or not much deep geothermal reservoirs with temperature below 100 C, the two phase closed loop thermosyphon can transfer heat very efficiently. In this case the most important task is the enhancement of the heat transfer mechanism between the heat exchanger and the aquifer. In the first part of the paper a review of particular applications connected to the geothermal heat pipe applications is proposed, then an analysis of the main technical elements regarding the geothermal aquifer exploitation through two phase thermosyphon systems are given. Some guidelines for power systems sizing are discussed and a proposal for the design of a single borehole heat extraction system with binary cycle utilization is provided.
2013
Franco, Alessandro; Vaccaro, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/208457
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 46
social impact