Measuring and monitoring through wearable technology parameters related to human movement, posture, and gesture are gaining momentum because of their wide range of potential applications in daily-life conditions. In previous studies, carbon elastomers (CEs) have been used as strain sensors. Recent developments of CE sensors mathematical modeling demonstrated that the CEs can be used as electrogoniometers. It was proved that for small local curvatures of CE layers, the resistance of a strip constituting a layer depends only on the total curvature of the same layer and not on the particular shape that the sensor keeps in adherence with a surface. Further, it was proved, theoretically and experimentally, that a double-layer configuration provides better accuracy with respect to a single-layer configuration. These results have been obtained under the hypothesis that the device was bent, but not extended. In this paper, we substituted the inextensible insulating layer in the sensors with an elastic one, allowing the system to extend its length. This improvement required further study to make it fit for biomechanical applications following epithelial deformations produced by joint movements and minimizes skin motion artifacts. © 2001-2012 IEEE.

Modeling and characterization of extensible wearable textile-based electrogoniometers

LORUSSI, FEDERICO;GALATOLO, STEFANO;DE ROSSI, DANILO EMILIO
2013-01-01

Abstract

Measuring and monitoring through wearable technology parameters related to human movement, posture, and gesture are gaining momentum because of their wide range of potential applications in daily-life conditions. In previous studies, carbon elastomers (CEs) have been used as strain sensors. Recent developments of CE sensors mathematical modeling demonstrated that the CEs can be used as electrogoniometers. It was proved that for small local curvatures of CE layers, the resistance of a strip constituting a layer depends only on the total curvature of the same layer and not on the particular shape that the sensor keeps in adherence with a surface. Further, it was proved, theoretically and experimentally, that a double-layer configuration provides better accuracy with respect to a single-layer configuration. These results have been obtained under the hypothesis that the device was bent, but not extended. In this paper, we substituted the inextensible insulating layer in the sensors with an elastic one, allowing the system to extend its length. This improvement required further study to make it fit for biomechanical applications following epithelial deformations produced by joint movements and minimizes skin motion artifacts. © 2001-2012 IEEE.
2013
Lorussi, Federico; Galatolo, Stefano; R., Bartalesi; DE ROSSI, DANILO EMILIO
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/215528
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? ND
social impact