BACKGROUND: Techniques of mixed reality can successfully be used in preoperative planning of laparoscopic and robotic procedures and to guide surgical dissection and enhance its accuracy. METHODS: A computer-generated three-dimensional (3D) model of the vascular anatomy of the spleen was obtained from the computed tomography (CT) dataset of a patient with a 3-cm splenic artery aneurysm. Using an environmental infrared localizer and a stereoscopic helmet, the surgeon can see the patient's anatomy in transparency (augmented or mixed reality). This arrangement simplifies correct positioning of trocars and locates surgical dissection directly on top of the aneurysm. In this way the surgeon limits unnecessary dissection, leaving intact the blood supply from the short gastric vessels and other collaterals. Based on preoperative planning, we were able to anticipate that the vascular exclusion of the aneurysm would result in partial splenic ischemia. To re-establish the flow to the spleen, end-to-end robotic anastomosis of the splenic artery with the Da Vinci surgical system was then performed. Finally, the aneurysm was fenestrated to exclude arterial refilling. RESULTS: The postoperative course was uneventful. A control CT scan 4 weeks after surgery showed a well-perfused and homogeneous splenic parenchyma. The final 3D model showed the fenestrated calcified aneurysm and patency of the re-anastomosed splenic artery. CONCLUSIONS: The described technique of robotic vascular exclusion of a splenic artery aneurysm, followed by re-anastomosis of the vessel, clearly demonstrates how this technology can reduce the invasiveness of the procedure, obviating an otherwise necessary splenectomy. Also, the use of intraoperative mixed-reality technology proved very useful in this case and is expected to play an increasing role in the operating room of the future.

Mixed reality for robotic treatment of a splenic artery aneurysm

MORELLI, LUCA;FERRARI, MAURO;FERRARI, VINCENZO;A. Moglia;
2010-01-01

Abstract

BACKGROUND: Techniques of mixed reality can successfully be used in preoperative planning of laparoscopic and robotic procedures and to guide surgical dissection and enhance its accuracy. METHODS: A computer-generated three-dimensional (3D) model of the vascular anatomy of the spleen was obtained from the computed tomography (CT) dataset of a patient with a 3-cm splenic artery aneurysm. Using an environmental infrared localizer and a stereoscopic helmet, the surgeon can see the patient's anatomy in transparency (augmented or mixed reality). This arrangement simplifies correct positioning of trocars and locates surgical dissection directly on top of the aneurysm. In this way the surgeon limits unnecessary dissection, leaving intact the blood supply from the short gastric vessels and other collaterals. Based on preoperative planning, we were able to anticipate that the vascular exclusion of the aneurysm would result in partial splenic ischemia. To re-establish the flow to the spleen, end-to-end robotic anastomosis of the splenic artery with the Da Vinci surgical system was then performed. Finally, the aneurysm was fenestrated to exclude arterial refilling. RESULTS: The postoperative course was uneventful. A control CT scan 4 weeks after surgery showed a well-perfused and homogeneous splenic parenchyma. The final 3D model showed the fenestrated calcified aneurysm and patency of the re-anastomosed splenic artery. CONCLUSIONS: The described technique of robotic vascular exclusion of a splenic artery aneurysm, followed by re-anastomosis of the vessel, clearly demonstrates how this technology can reduce the invasiveness of the procedure, obviating an otherwise necessary splenectomy. Also, the use of intraoperative mixed-reality technology proved very useful in this case and is expected to play an increasing role in the operating room of the future.
2010
Pietrabissa, A.; Morelli, Luca; Ferrari, Mauro; Peri, A.; Ferrari, Vincenzo; Moglia, A.; Pugliese, L.; Guarracino, F.; Mosca, F.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/429886
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
social impact