The purpose of this publication was to present and evaluate the methods for reference dosimetry in the epithermal neutron beam at the neutron capture therapy facility at Studsvik. Measurements were performed in a PMMA phantom and in air using ionization chambers and activation probes in order to calibrate the epithermal neutron beam. Appropriate beam-dependant calibration factors were determined using Monte Carlo methods for the detectors used in the present publication. Using the presented methodology, the photon, neutron and total absorbed dose to PMMA was determined with an estimated uncertainty of +/- 5.0%, +/- 25%, and +/- 5.5% (2 SD), respectively. The uncertainty of the determination of the photon absorbed dose was comparable to the case in conventional radiotherapy, while the uncertainty of the neutron absorbed dose is much higher using the present methods. The thermal neutron group fluence, i.e., the neutron fluence in the energy interval 0-0.414 eV, was determined with an estimated uncertainty of +/- 2.8% (2 SD), which is acceptable for dosimetry in epithermal neutron beams.

Reference dosimetry at the boron neutron capture therapy facility at Studsvik

GIUSTI, VALERIO;
2003-01-01

Abstract

The purpose of this publication was to present and evaluate the methods for reference dosimetry in the epithermal neutron beam at the neutron capture therapy facility at Studsvik. Measurements were performed in a PMMA phantom and in air using ionization chambers and activation probes in order to calibrate the epithermal neutron beam. Appropriate beam-dependant calibration factors were determined using Monte Carlo methods for the detectors used in the present publication. Using the presented methodology, the photon, neutron and total absorbed dose to PMMA was determined with an estimated uncertainty of +/- 5.0%, +/- 25%, and +/- 5.5% (2 SD), respectively. The uncertainty of the determination of the photon absorbed dose was comparable to the case in conventional radiotherapy, while the uncertainty of the neutron absorbed dose is much higher using the present methods. The thermal neutron group fluence, i.e., the neutron fluence in the energy interval 0-0.414 eV, was determined with an estimated uncertainty of +/- 2.8% (2 SD), which is acceptable for dosimetry in epithermal neutron beams.
2003
MUNCK AF ROSENSCHOLD, Pm; Giusti, Valerio; Ceberg, Cp; Capala, J; SKOLD K., AND PERSSON BRR
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/76289
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 9
social impact