The material critical distance is often deduced from plain and notched specimens, instead of experimentally measuring the (long) crack threshold, which is a challenging task and not adequate in some cases. A dedicated V-notched specimen was proposed along with a dimensionless numerical procedure to derive the critical distance from the fatigue stress concentration factor, by implementing both the line and the point methods. An experimental validation activity is provided here on 42CrMo4+QT steel, focusing on how the critical distance result is sensitive to the actual local radius, the specimen sharpness, and the choice between the line or the point method. The determination of the critical distance with the point method systematically provides higher values than the line method. However, these length discrepancies do not produce large effects in terms of the component strength assessment if the same method for the fatigue limit evaluation is used. By alternatively considering the specimen not involved in the critical distance determination, as a potential design component, the prediction accuracy was evaluated. This analysis confirmed that a small notch radius is recommended for the fatigue strength assessment of larger radius notches or even of a crack, whereas by deducing the critical distance from a blunt notch, a noticeable inaccuracy can be found on smaller radius and crack threshold.

Sensibility analysis of the fatigue critical distance values assessed by combining plain and notched cylindrical specimens

C. Santus
;
2018-01-01

Abstract

The material critical distance is often deduced from plain and notched specimens, instead of experimentally measuring the (long) crack threshold, which is a challenging task and not adequate in some cases. A dedicated V-notched specimen was proposed along with a dimensionless numerical procedure to derive the critical distance from the fatigue stress concentration factor, by implementing both the line and the point methods. An experimental validation activity is provided here on 42CrMo4+QT steel, focusing on how the critical distance result is sensitive to the actual local radius, the specimen sharpness, and the choice between the line or the point method. The determination of the critical distance with the point method systematically provides higher values than the line method. However, these length discrepancies do not produce large effects in terms of the component strength assessment if the same method for the fatigue limit evaluation is used. By alternatively considering the specimen not involved in the critical distance determination, as a potential design component, the prediction accuracy was evaluated. This analysis confirmed that a small notch radius is recommended for the fatigue strength assessment of larger radius notches or even of a crack, whereas by deducing the critical distance from a blunt notch, a noticeable inaccuracy can be found on smaller radius and crack threshold.
File in questo prodotto:
File Dimensione Formato  
Sensibility analysis.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 809.1 kB
Formato Adobe PDF
809.1 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/910547
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact