Aims: High-touch surfaces cleaning and disinfection require the adoption of effective and proper executed protocols, especially during carbapenem-resistant Acinetobacter baumannii (CRAB) endemo-epidemic situations. We evaluated the effectiveness and residual disinfectant activity of disposable pre-impregnated wipes (Modified Operative Protocol, MOP) in reducing environmental bioburden versus a two-step Standard Operative Protocol (SOP) in a 12-bed Intensive Care Unit. Methods: Five high-touch surfaces were cleaned and disinfected either according to the SOP (alcohol-based cleaning and chlorine-based disinfection) or using quaternary ammonium compounds-based disposable wipes (MOP). Sampling was performed before each procedure and at 0.5, 2.5, 4.5 and 6.5 h after (560 sites). Total viable count (TVC) was evaluated according to Italian hygiene standard (<50 CFU/24 cm2). Clinical and environmental CRAB strains isolated were genotyped. Results: On non-electromedical surfaces the difference between TVC before procedure and at each of the following times was significant only for the MOP (p < 0.05, Wilcoxon test). Using the MOP, only 7.4% (10/135) of sites showed TVC >50 CFU/24 cm2 (hygiene failures) versus 18.9% (25/132) after SOP (p < 0.05, Fisher’s Exact test). On infusion pumps a higher number of hygiene failures was observed after the SOP (7/44, 15.9%) compared with the MOP (4/45, 8.9%). Genotyping highlighted a common source of infection. Conclusion: On high-touch surfaces, the use of disposable wipes by in-house auxiliary nurses may represent a more effective alternative to standard cleaning and disinfection procedure performed by outsourced cleaning services, showing effectiveness in reducing microbial contamination and residual disinfection activity up to 6.5 h.

Improving cleaning and disinfection of high-touch surfaces in intensive care during carbapenem-resistant acinetobacter baumannii endemo-epidemic situations

Casini, Beatrice;Totaro, Michele;Valentini, Paola;Baggiani, Angelo;Lopalco, Pietro Luigi;Privitera, Gaetano Pierpaolo
2018-01-01

Abstract

Aims: High-touch surfaces cleaning and disinfection require the adoption of effective and proper executed protocols, especially during carbapenem-resistant Acinetobacter baumannii (CRAB) endemo-epidemic situations. We evaluated the effectiveness and residual disinfectant activity of disposable pre-impregnated wipes (Modified Operative Protocol, MOP) in reducing environmental bioburden versus a two-step Standard Operative Protocol (SOP) in a 12-bed Intensive Care Unit. Methods: Five high-touch surfaces were cleaned and disinfected either according to the SOP (alcohol-based cleaning and chlorine-based disinfection) or using quaternary ammonium compounds-based disposable wipes (MOP). Sampling was performed before each procedure and at 0.5, 2.5, 4.5 and 6.5 h after (560 sites). Total viable count (TVC) was evaluated according to Italian hygiene standard (<50 CFU/24 cm2). Clinical and environmental CRAB strains isolated were genotyped. Results: On non-electromedical surfaces the difference between TVC before procedure and at each of the following times was significant only for the MOP (p < 0.05, Wilcoxon test). Using the MOP, only 7.4% (10/135) of sites showed TVC >50 CFU/24 cm2 (hygiene failures) versus 18.9% (25/132) after SOP (p < 0.05, Fisher’s Exact test). On infusion pumps a higher number of hygiene failures was observed after the SOP (7/44, 15.9%) compared with the MOP (4/45, 8.9%). Genotyping highlighted a common source of infection. Conclusion: On high-touch surfaces, the use of disposable wipes by in-house auxiliary nurses may represent a more effective alternative to standard cleaning and disinfection procedure performed by outsourced cleaning services, showing effectiveness in reducing microbial contamination and residual disinfection activity up to 6.5 h.
2018
Casini, Beatrice; Righi, Anna; De Feo, Nunzio; Totaro, Michele; Giorgi, Serena; Zezza, Lavinia; Valentini, Paola; Tagliaferri, Enrico; Costa, Anna Laura; Barnini, Simona; Baggiani, Angelo; Lopalco, Pietro Luigi; Malacarne, Paolo; Privitera, Gaetano Pierpaolo
File in questo prodotto:
File Dimensione Formato  
PhysRevD.100.072002.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 810.98 kB
Formato Adobe PDF
810.98 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/937780
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact