Counterpart test on SB-LOCA was conducted in early ‘90 on four ITF + one in early 2000’s - LOBI – power-to-volume, Kv = 1/712 [KWU-PWR, 4 loops] - SPES – power-to-volume, Kv = 1/427 [Westinghouse-PWR, 3 loops] - BETHSY – power-to-volume, Kv = 1/100 [French-PWR, 3 loops] - LSTF – power-to-volume, Kv = 1/48 [Westinghouse-PWR, 4 loops] - PSB – power-to-volume, Kv = 1/300 [VVER-1000] - Performed in 2000’s Break area/ ITF volume ≃ 6.52e-5 (6%-4% break at reference reactors scale) Main features of the tests (some distortions exit): - SB-LOCA in CL – Loop with PRZ - Low initial power (∼ 10%) – LOBI and SPES tests repeated at high power (100%) - Same core outlet temperature - SG interconnected and isolated - MCP trip occurs - HPIS not available - Accumulator injection at 42 bar – Intact loops - LPIS simulated in LOBI and SPES (and PSB) – Intact loops Detailed evaluation of the experimental database performed Extensive post-test analyses conducted with RELAP5 and CATHARE2 codes

SB-LOCA Counterpart Test - LOBI, SPES, BETHSY, LSTF, PSB - Preliminary ATLAS calculation

D'Auria F.
Co-primo
Supervision
;
2020-01-01

Abstract

Counterpart test on SB-LOCA was conducted in early ‘90 on four ITF + one in early 2000’s - LOBI – power-to-volume, Kv = 1/712 [KWU-PWR, 4 loops] - SPES – power-to-volume, Kv = 1/427 [Westinghouse-PWR, 3 loops] - BETHSY – power-to-volume, Kv = 1/100 [French-PWR, 3 loops] - LSTF – power-to-volume, Kv = 1/48 [Westinghouse-PWR, 4 loops] - PSB – power-to-volume, Kv = 1/300 [VVER-1000] - Performed in 2000’s Break area/ ITF volume ≃ 6.52e-5 (6%-4% break at reference reactors scale) Main features of the tests (some distortions exit): - SB-LOCA in CL – Loop with PRZ - Low initial power (∼ 10%) – LOBI and SPES tests repeated at high power (100%) - Same core outlet temperature - SG interconnected and isolated - MCP trip occurs - HPIS not available - Accumulator injection at 42 bar – Intact loops - LPIS simulated in LOBI and SPES (and PSB) – Intact loops Detailed evaluation of the experimental database performed Extensive post-test analyses conducted with RELAP5 and CATHARE2 codes
2020
File in questo prodotto:
File Dimensione Formato  
11-CT_ATLAS_r2_FONESYS.pdf

solo utenti autorizzati

Descrizione: power point presentation of the ideas of the authors
Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.51 MB
Formato Adobe PDF
2.51 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1064120
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact