On March 25th 2019, the Belle II detector recorded the first collisions delivered by the SuperKEKB accelerator. This marked the beginning of the physics run with vertex detector.The vertex detector was aligned initially with cosmic ray tracks without magnetic field simultaneously with the drift chamber. The alignment method is based on Millepede II and the General Broken Lines track model and includes also the muon system or primary vertex position alignment. To control weak modes, we employ sensitive validation tools and various track samples can be used as alignment input, from straight cosmic tracks to mass-constrained decays.With increasing luminosity and experience, the alignment is approaching the target performance, crucial for the first physics analyses in the era of Super-B-Factories. We will present the software framework for the detector calibration and alignment, the results from the first physics run and the prospects in view of the experience with the first data.

Alignment for the first precision measurements at Belle II

Batignani, Giovanni;Bettarini, Stefano;Casarosa, Giulia;Corona, Luigi;de Marino, Gaetano;Forti, Francesco;Paladino, Antonio;Paoloni, Eugenio;Rizzo, Giuliana;Zani, Laura;
2020-01-01

Abstract

On March 25th 2019, the Belle II detector recorded the first collisions delivered by the SuperKEKB accelerator. This marked the beginning of the physics run with vertex detector.The vertex detector was aligned initially with cosmic ray tracks without magnetic field simultaneously with the drift chamber. The alignment method is based on Millepede II and the General Broken Lines track model and includes also the muon system or primary vertex position alignment. To control weak modes, we employ sensitive validation tools and various track samples can be used as alignment input, from straight cosmic tracks to mass-constrained decays.With increasing luminosity and experience, the alignment is approaching the target performance, crucial for the first physics analyses in the era of Super-B-Factories. We will present the software framework for the detector calibration and alignment, the results from the first physics run and the prospects in view of the experience with the first data.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1137536
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 2
social impact