The development of foldable heat transfer devices is currently a quite intriguing technological challenge in the field of thermal management. Due to its simple structure (i.e. capillary tube without any wick structure inside), the Pulsating Heat Pipe is one of the most promising candidate to be applied to foldable devices. A possible solution is to realize a PHP with the adiabatic section formed as a coil. In this case the adiabatic section is very long and the performance of the PHP can be largely affected. This paper presents the results of the comparison between two twin PHPs built with the same geometry but different adiabatic section shapes (planar and coil). A full thermal characterization of the planar assessment for different working fluids has been performed: HFE-7000 (filling ratio: 70%) shows the best thermal behavior in horizontal orientation. On the other hand, the coiled PHP has been tested under different orientations and folding configurations (different mutual locations of the evaporator and condenser with respect to gravity) and compared with the planar reference case. The coiled PHP in some configurations seems to present worse thermal performances than the planar one.

Experimental investigation of a coil shaped deployable pulsating heat pipe

Roberta Perna;Mauro Mameli;Sauro Filippeschi
2023-01-01

Abstract

The development of foldable heat transfer devices is currently a quite intriguing technological challenge in the field of thermal management. Due to its simple structure (i.e. capillary tube without any wick structure inside), the Pulsating Heat Pipe is one of the most promising candidate to be applied to foldable devices. A possible solution is to realize a PHP with the adiabatic section formed as a coil. In this case the adiabatic section is very long and the performance of the PHP can be largely affected. This paper presents the results of the comparison between two twin PHPs built with the same geometry but different adiabatic section shapes (planar and coil). A full thermal characterization of the planar assessment for different working fluids has been performed: HFE-7000 (filling ratio: 70%) shows the best thermal behavior in horizontal orientation. On the other hand, the coiled PHP has been tested under different orientations and folding configurations (different mutual locations of the evaporator and condenser with respect to gravity) and compared with the planar reference case. The coiled PHP in some configurations seems to present worse thermal performances than the planar one.
File in questo prodotto:
File Dimensione Formato  
HPAUS-77.pdf

solo utenti autorizzati

Descrizione: Full paper accepted
Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - accesso privato/ristretto
Dimensione 994.67 kB
Formato Adobe PDF
994.67 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1163109
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact