Pre-stressed concrete with post-tensioned (PT) cables historically represented an attractive alternative to ordinary reinforced concrete (RC). A wide portion of the worldwide existing concrete bridges was PT. As the nominal service life of those structures expires, several collapses occurred, highlighting the problem of the inspection. The main issue is that PT cables may be affected by relevant corrosion phenomena related to the presence of air or water inside the ducts: such ‘hidden’ defects need to be determined through reliable testing methodologies. This paper presents the in-progress research aiming to quantify the influence of the damage of the single cable on the entire structure. The case study is an Italian viaduct composed of simply supported beams connected by an upper slab. An extensive investigation campaign was carried out to locate and quantify the damage. Starting from the data collected on-site a series of damage conditions of cables can be simulated.

Inspection and assessment of PT structures: results from application to an existing bridge

Isabella Mazzatura;Silvia Caprili;Walter Salvatore;Andrea Piscini
2023-01-01

Abstract

Pre-stressed concrete with post-tensioned (PT) cables historically represented an attractive alternative to ordinary reinforced concrete (RC). A wide portion of the worldwide existing concrete bridges was PT. As the nominal service life of those structures expires, several collapses occurred, highlighting the problem of the inspection. The main issue is that PT cables may be affected by relevant corrosion phenomena related to the presence of air or water inside the ducts: such ‘hidden’ defects need to be determined through reliable testing methodologies. This paper presents the in-progress research aiming to quantify the influence of the damage of the single cable on the entire structure. The case study is an Italian viaduct composed of simply supported beams connected by an upper slab. An extensive investigation campaign was carried out to locate and quantify the damage. Starting from the data collected on-site a series of damage conditions of cables can be simulated.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1189265
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact