Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Particularly important are the decays of the Higgs boson resulting in electromagnetic particles in the final state, as well as the searches for very high mass resonances decaying into energetic photons or electrons. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented values, using 25 ns bunch spacing. High pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms, to maintain the best possible performance in these more challenging conditions. The energy response of the detector must be precisely calibrated and monitored to achieve and maintain the excellent performance obtained in Run I in terms of energy scale and resolution. A dedicated calibration of each detector channel is performed with physics events exploiting electrons from W and Z boson decays, photons from $pi^{0}$/$eta$ decays, and from the azimuthally symmetric energy distribution of minimum bias events. This contribution describes the calibration strategies and the performance of the CMS ECAL throughout Run II and its role in precision physics measurements with CMS involving electrons and photons.

Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements

Cipriani, Marco
2018-01-01

Abstract

Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Particularly important are the decays of the Higgs boson resulting in electromagnetic particles in the final state, as well as the searches for very high mass resonances decaying into energetic photons or electrons. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented values, using 25 ns bunch spacing. High pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms, to maintain the best possible performance in these more challenging conditions. The energy response of the detector must be precisely calibrated and monitored to achieve and maintain the excellent performance obtained in Run I in terms of energy scale and resolution. A dedicated calibration of each detector channel is performed with physics events exploiting electrons from W and Z boson decays, photons from $pi^{0}$/$eta$ decays, and from the azimuthally symmetric energy distribution of minimum bias events. This contribution describes the calibration strategies and the performance of the CMS ECAL throughout Run II and its role in precision physics measurements with CMS involving electrons and photons.
File in questo prodotto:
File Dimensione Formato  
Cipriani_Performance_2018.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 6.5 MB
Formato Adobe PDF
6.5 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1215714
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact