This work proposes some heat transfer pulsating devices as interesting alternative solution to the LHP (Loop Heat Pipe) and CPL (Capillary Pumped Loop). These devices, named pulsated two-phase thermosyphon (PTPT) by the authors, have been studied, classified and experimentally observed in previous works. In this paper the operating principles of the PTPT devices in comparison with LHPs or CPLs for thermal control applications are illustrated. Although the LHP and CPL operate in a steady state regime of heat transfer and PTPT operates in a stabilized periodic regime, some important comparisons are presented.

Pulsated Two-Phase Thermosyphons for Electronic Equipment Thermal Control

FANTOZZI, FABIO;FILIPPESCHI, SAURO
2002-01-01

Abstract

This work proposes some heat transfer pulsating devices as interesting alternative solution to the LHP (Loop Heat Pipe) and CPL (Capillary Pumped Loop). These devices, named pulsated two-phase thermosyphon (PTPT) by the authors, have been studied, classified and experimentally observed in previous works. In this paper the operating principles of the PTPT devices in comparison with LHPs or CPLs for thermal control applications are illustrated. Although the LHP and CPL operate in a steady state regime of heat transfer and PTPT operates in a stabilized periodic regime, some important comparisons are presented.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/191439
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact