This paper presents the results of a clinical trial employing the PERCRO L-Exos (Light-Exoskeleton) system, which is a 5-DoF force-feedback exoskeleton for the right arm, for robotic-assisted rehabilitation. The device has demonstrated itself suitable for robotic arm rehabilitation therapy when integrated with a Virtual Reality (VR) system. Three different schemes of therapy in VR have been tested in the clinical evaluation trial, which was conducted at the Santa Chiara Hospital in Pisa with nine chronic stroke patients. The results of this clinical trial, both in terms of patients performance improvements in the proposed exercises and in terms of improvements in the standard clinical scales which have been used to monitor patients progresses will be reported and discussed throughout the paper. It is to be noted that statistically significant improvements have been demonstrated in terms of Fugl-Meyer scores, Ashworth scale and increments of active and passive ROMs on shoulder, elbow and wrist joints of the impaired limb. ©2008 IEEE.

Robot-mediated arm rehabilitation in virtual environments for chronic stroke patients: A clinical study

CARBONCINI, MARIA CHIARA;ROSSI, BRUNO
2008-01-01

Abstract

This paper presents the results of a clinical trial employing the PERCRO L-Exos (Light-Exoskeleton) system, which is a 5-DoF force-feedback exoskeleton for the right arm, for robotic-assisted rehabilitation. The device has demonstrated itself suitable for robotic arm rehabilitation therapy when integrated with a Virtual Reality (VR) system. Three different schemes of therapy in VR have been tested in the clinical evaluation trial, which was conducted at the Santa Chiara Hospital in Pisa with nine chronic stroke patients. The results of this clinical trial, both in terms of patients performance improvements in the proposed exercises and in terms of improvements in the standard clinical scales which have been used to monitor patients progresses will be reported and discussed throughout the paper. It is to be noted that statistically significant improvements have been demonstrated in terms of Fugl-Meyer scores, Ashworth scale and increments of active and passive ROMs on shoulder, elbow and wrist joints of the impaired limb. ©2008 IEEE.
2008
9781424416479
File in questo prodotto:
File Dimensione Formato  
2008 ICRA.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 588.14 kB
Formato Adobe PDF
588.14 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/804868
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact