Modern computer codes play an important role in nuclear safety analysis. This paper presents the investigation of a station blackout accident at a VVER 1000 NPP with the codes Relap5 mod 3.2 Scdap and Melcor 1.8.5. A special interest was taken in the hydrogen production. A large amount of hydrogen could pose a serious threat to the containment. User choices have a considerable influence on the amount of produced hydrogen. The results from the calculations are presented and discussed. The results show in general a good agreement between the calculations.
Investigation of H2 generation during a SBO for a VVER 1000-320 using the codes Relap5/SCDAP and MELCOR
D'AURIA, FRANCESCO SAVERIO;
2004-01-01
Abstract
Modern computer codes play an important role in nuclear safety analysis. This paper presents the investigation of a station blackout accident at a VVER 1000 NPP with the codes Relap5 mod 3.2 Scdap and Melcor 1.8.5. A special interest was taken in the hydrogen production. A large amount of hydrogen could pose a serious threat to the containment. User choices have a considerable influence on the amount of produced hydrogen. The results from the calculations are presented and discussed. The results show in general a good agreement between the calculations.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.