The paper concerns about CFD calculations of LBE flowing in the wire-wrapped hexagonal array electrical pin bundle of NACIE-UP facility. Pressure drop and friction factor analyses are performed in order to find possible matching between CFD results and available correlations to be used in the frame of forthcoming applications involving CFD/System Codes (STH) coupling calculations. The Fuel Pin Simulator of the NACIE-UP facility is presently considered for calculations; post-test analyses are performed as well in order to understand capabilities and uncertainties of available CFD codes and techniques in the liquid metal thermal hydraulics field. Calculations were performed using the commercial codes STAR-CCM+ and ANSYS FLUENT and promising results were provided. In particular, good matching between CFD results and predictions from the Cheng and Todreas (1986) correlation is observed in the frame of the pressure drop analysis. Post-test analyses aiming at comparing the measured and calculated temperature values for three selected operating conditions were performed; the adopted CFD tool reported good capabilities in reproducing the experimental results. Sensitivity analyses considering anomalous power distributions were also performed. The lesson drawn provided further comprehension of the involved phenomena and interesting information for future applications involving CFD/STH codes in coupling calculations.

NACIE-UP post-test simulations by CFD codes

Pucciarelli A.
Writing – Review & Editing
;
Forgione N.
Writing – Review & Editing
;
Galleni F.
Writing – Review & Editing
;
Martelli D.
Writing – Review & Editing
2020-01-01

Abstract

The paper concerns about CFD calculations of LBE flowing in the wire-wrapped hexagonal array electrical pin bundle of NACIE-UP facility. Pressure drop and friction factor analyses are performed in order to find possible matching between CFD results and available correlations to be used in the frame of forthcoming applications involving CFD/System Codes (STH) coupling calculations. The Fuel Pin Simulator of the NACIE-UP facility is presently considered for calculations; post-test analyses are performed as well in order to understand capabilities and uncertainties of available CFD codes and techniques in the liquid metal thermal hydraulics field. Calculations were performed using the commercial codes STAR-CCM+ and ANSYS FLUENT and promising results were provided. In particular, good matching between CFD results and predictions from the Cheng and Todreas (1986) correlation is observed in the frame of the pressure drop analysis. Post-test analyses aiming at comparing the measured and calculated temperature values for three selected operating conditions were performed; the adopted CFD tool reported good capabilities in reproducing the experimental results. Sensitivity analyses considering anomalous power distributions were also performed. The lesson drawn provided further comprehension of the involved phenomena and interesting information for future applications involving CFD/STH codes in coupling calculations.
2020
Pucciarelli, A.; Barone, G.; Forgione, N.; Galleni, F.; Martelli, D.
File in questo prodotto:
File Dimensione Formato  
PUCCIARELLI_Manuscript_revised.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 3.05 MB
Formato Adobe PDF
3.05 MB Adobe PDF Visualizza/Apri
NACIE UP.pdf

non disponibili

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - accesso privato/ristretto
Dimensione 2.2 MB
Formato Adobe PDF
2.2 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1022368
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact