The Aleph detector is installed on the LEP electron-positron storage ring. Its central tracking detector, a time projection chamber (TPC), has about 50000 channels of sampling electronics. The digitized signals are processed by 72 double-width Fastbus modules built around an MC 68020 processor. The time projection processor is described, and the solutions, both hardware and software, adopted to run and manage such a complex system in a Fastbus-VAX environment are discussed. Practical experience with the system is reported

The Read-out Processors of the Aleph Time Projection Chamber and Their Performance

FIDECARO, FRANCESCO;CIOCCI, MARIA AGNESE;
1990-01-01

Abstract

The Aleph detector is installed on the LEP electron-positron storage ring. Its central tracking detector, a time projection chamber (TPC), has about 50000 channels of sampling electronics. The digitized signals are processed by 72 double-width Fastbus modules built around an MC 68020 processor. The time projection processor is described, and the solutions, both hardware and software, adopted to run and manage such a complex system in a Fastbus-VAX environment are discussed. Practical experience with the system is reported
1990
Blucher, E; Fagerstrom, J; Haywood, S; Larsson, U; Lehraus, I; Loefstedt, B; Lohse, T; May, J; Minten, A; Richstein, J; Richter, W; Roth, A; Schlatter...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/10486
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact