The combination of structural and thermal efficiency is a new frontier in civil engineering. Indeed, the retrofitting strategies should optimize costs and technical solutions from these two points of view. If a technical solution is able to provide an improvement of both structural and energetic behavior, then the utility of the intervention can better justify the economic investment. In this paper, a meso-scale approach (i.e., façade-scale) for integrated interventions applied on masonry façades is proposed. The structural performance of the façade is evaluated by considering base shear and ductility of the structural element through non-linear static analyses. Moreover, the thermal indicator, that is the thermal transmittance, is computed with a simplified approach in terms of an equivalent wall, taking into account the role of the windows and doors of the façade. As proof of concept, the procedure is applied to a façade of an existing masonry building. Economic and environmental iso-cost curves are obtained to tune the interventions conceived for a real case study, analyzing the benefit offered by different retrofitting solutions.

Integrated Cost-Analysis Approach for Seismic and Thermal Improvement of Masonry Building Façades

Giresini, Linda
Primo
;
2020-01-01

Abstract

The combination of structural and thermal efficiency is a new frontier in civil engineering. Indeed, the retrofitting strategies should optimize costs and technical solutions from these two points of view. If a technical solution is able to provide an improvement of both structural and energetic behavior, then the utility of the intervention can better justify the economic investment. In this paper, a meso-scale approach (i.e., façade-scale) for integrated interventions applied on masonry façades is proposed. The structural performance of the façade is evaluated by considering base shear and ductility of the structural element through non-linear static analyses. Moreover, the thermal indicator, that is the thermal transmittance, is computed with a simplified approach in terms of an equivalent wall, taking into account the role of the windows and doors of the façade. As proof of concept, the procedure is applied to a façade of an existing masonry building. Economic and environmental iso-cost curves are obtained to tune the interventions conceived for a real case study, analyzing the benefit offered by different retrofitting solutions.
2020
Giresini, Linda; Paone, Simona; Sassu, Mauro
File in questo prodotto:
File Dimensione Formato  
2020 GiresiniPaoneSassu IntegratedApproachRocchettaVara.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 3 MB
Formato Adobe PDF
3 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1051180
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact