Advantages of dried blood spot include low invasiveness, ease and low cost of sample collection, transport, and storage. We used tandem mass spectrometry (LC-MS/MS) to determine phenobarbital levels on dried blood spot specimens and compared this methodology to commercially available particle enhanced turbidimetric inhibition immunoassay (PETINIA) in plasma/serum samples. The calibration curve in matrix using D(5)-phenobarbital as internal standard was linear in the phenobarbital concentration range of 1-100 mg/L (correlation coefficient 0.9996). The coefficients of variation in blood spots ranged 2.29-6.71% and the accuracy ranged 96.54-103.87%. There were no significant differences between the concentrations measured using PETINA and LC-MS/MS (both had similar precision and accuracy) however, LC-MS/MS allows at least 1.5 times higher throughput of phenobarbital analysis and additionally offers ease of sample collection which is particularly important for newborns or small infants.

A new rapid micromethod for the assay of phenobarbital from dried blood spots by LC-tandem mass spectrometry

Filippi L.;
2009-01-01

Abstract

Advantages of dried blood spot include low invasiveness, ease and low cost of sample collection, transport, and storage. We used tandem mass spectrometry (LC-MS/MS) to determine phenobarbital levels on dried blood spot specimens and compared this methodology to commercially available particle enhanced turbidimetric inhibition immunoassay (PETINIA) in plasma/serum samples. The calibration curve in matrix using D(5)-phenobarbital as internal standard was linear in the phenobarbital concentration range of 1-100 mg/L (correlation coefficient 0.9996). The coefficients of variation in blood spots ranged 2.29-6.71% and the accuracy ranged 96.54-103.87%. There were no significant differences between the concentrations measured using PETINA and LC-MS/MS (both had similar precision and accuracy) however, LC-MS/MS allows at least 1.5 times higher throughput of phenobarbital analysis and additionally offers ease of sample collection which is particularly important for newborns or small infants.
2009
la Marca, G.; Malvagia, S.; Filippi, L.; Luceri, F.; Moneti, G.; Guerrini, R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1072244
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 46
  • ???jsp.display-item.citation.isi??? ND
social impact