This paper aims at proposing fast and plain design tools to evaluate the best energy application for deep borehole heat exchangers, exploiting geothermal resources. Exergy efficiency has been chosen as a performance index. Five possible utilization solutions have been analyzed: district heating, adsorption cooling, ORC power production, a thermal cascade system, and combined heat and power configuration. An extensive sensitivity analysis on source characteristics and well geometry has been performed to find the design criteria that ensure the maximum exergy performance. Results show that configurations involving district heating are recommended for exclusive power production. If optimized, district heating exergy efficiency can reach values in the range 40%–50% when a geothermal source at the well bottom is lower than 300 °C. For higher values, the combined heat and power production is a preferable choice, reaching an exergy efficiency of up to 60%. Design charts are also provided to read first-attempt values of the well operative temperatures and flow rate to maximize exergy efficiency for each utilization layouts.

Producing geothermal energy with a deep borehole heat exchanger: Exergy optimization of different applications and preliminary design criteria

P, Conti
Secondo
;
2021-01-01

Abstract

This paper aims at proposing fast and plain design tools to evaluate the best energy application for deep borehole heat exchangers, exploiting geothermal resources. Exergy efficiency has been chosen as a performance index. Five possible utilization solutions have been analyzed: district heating, adsorption cooling, ORC power production, a thermal cascade system, and combined heat and power configuration. An extensive sensitivity analysis on source characteristics and well geometry has been performed to find the design criteria that ensure the maximum exergy performance. Results show that configurations involving district heating are recommended for exclusive power production. If optimized, district heating exergy efficiency can reach values in the range 40%–50% when a geothermal source at the well bottom is lower than 300 °C. For higher values, the combined heat and power production is a preferable choice, reaching an exergy efficiency of up to 60%. Design charts are also provided to read first-attempt values of the well operative temperatures and flow rate to maximize exergy efficiency for each utilization layouts.
2021
Alimonti, C; Conti, P; Soldo, E
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1075709
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact