Purpose: While limb-sparing surgery is now possible for more than 80% of patients with bone tumours, wide resection is often required, necessitating bone reconstruction. This paper aims to present a surgical technique that combines the advantages of a hollow, titanium, custom-made prosthesis and the biological aspects of microsurgical flaps and bone graft. Patients and methods: From June 2016 to September 2017 at our institution, six consecutive patients with skeletal tumours underwent one-stage reconstructive surgery with concomitant implantation of a 3D-printed prosthesis. Results: At an average follow-up of 30 months (range: 18-45), no early complications were observed, and no implant removals were needed. One patient experienced a delayed haematogenous deep infection, which healed after surgical debridement. Three patients died of their underlying disease 18, 22, and 23 months after surgery, respectively. All flaps and custom reconstructions were successful, with primary osseointegration at a mean of four months (range: 2-7). Patients' average Musculoskeletal Tumour Society score was 23.2 (range: 18-28). Conclusion: A hollow, custom-made, titanium prosthesis filled with bone graft, used in conjunction with a microsurgical flap, may offer good osseointegration in different anatomic locations among a patient population with a high risk of infection, pseudarthrosis, and long-term mechanical complications. The surgical technique's advantages are preliminarily demonstrate

A hollow, custom-made prosthesis combined with a vascularized flap and bone graft for skeletal reconstruction after bone tumour resection

Rodolfo Capanna;
2021-01-01

Abstract

Purpose: While limb-sparing surgery is now possible for more than 80% of patients with bone tumours, wide resection is often required, necessitating bone reconstruction. This paper aims to present a surgical technique that combines the advantages of a hollow, titanium, custom-made prosthesis and the biological aspects of microsurgical flaps and bone graft. Patients and methods: From June 2016 to September 2017 at our institution, six consecutive patients with skeletal tumours underwent one-stage reconstructive surgery with concomitant implantation of a 3D-printed prosthesis. Results: At an average follow-up of 30 months (range: 18-45), no early complications were observed, and no implant removals were needed. One patient experienced a delayed haematogenous deep infection, which healed after surgical debridement. Three patients died of their underlying disease 18, 22, and 23 months after surgery, respectively. All flaps and custom reconstructions were successful, with primary osseointegration at a mean of four months (range: 2-7). Patients' average Musculoskeletal Tumour Society score was 23.2 (range: 18-28). Conclusion: A hollow, custom-made, titanium prosthesis filled with bone graft, used in conjunction with a microsurgical flap, may offer good osseointegration in different anatomic locations among a patient population with a high risk of infection, pseudarthrosis, and long-term mechanical complications. The surgical technique's advantages are preliminarily demonstrate
2021
Beltrami, Giovanni; 2, Gabriele Ristori; Galeotti, Alberto; Scoccianti, Guido; Tamburini, Angela; Campanacci, Domenico; Capanna, Rodolfo; Innocenti, M...espandi
File in questo prodotto:
File Dimensione Formato  
Hollow custon made prosthesis.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 2.58 MB
Formato Adobe PDF
2.58 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1077160
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact