Background To evaluate the accuracy of myocardial perfusion imaging (MPI) on a novel cadmium-zinc-thelluride camera in detecting significant coronary artery disease (CAD) in patients with atrial fibrillation (AF). Methods and results Seventy-four subjects with AF submitted to stress-rest MPI and coronary angiography were consecutively enrolled.One hundred and forty-eight patients in sinus rhythm, matched for age, sex, and type of stress-test protocol and with known coronary anatomy served as controls. The summed difference score, as measure of reversible myocardial ischaemia,was calculated. A coronary stenosis ≥70% was considered significant. The prevalence of significant CAD did not differ betweenAFpatients and controls. At receiving operating characteristic analysis MPI showed relevant accuracy in unmasking the presence of significantCADboth in AFand in control patients (areas under the curve 0.71 vs. 0.80, P for difference: 0.212).However, after stratifying patients according to the stress protocol, a significant interaction between the presence of AF and MPI diagnostic power was evident. While in the case of a vasodilator stress-test MPI diagnostic accuracy remained high in both groups of patients (P for difference: 0.664), in those submitted to an exercise stress-test the diagnostic power of MPI was significantly lower in the presence of AF (P for difference: 0.039), because of a lower specificity. Interestingly, at multivariate analysis, a lower exercise duration (P = 0.017) was the major predictor of reduced MPI specificity. Conclusion The presence of AF impairs MPI accuracy on the detection significant CAD. This effect was only apparent in the case of an exercise stress-test, while disappeared in patients submitted to vasodilator stress.

Evaluation of ischaemia in patients with atrial fibrillation: Impact of stress protocol on myocardial perfusion imaging accuracy

Liga R.
Co-primo
;
Giorgetti A.;
2015-01-01

Abstract

Background To evaluate the accuracy of myocardial perfusion imaging (MPI) on a novel cadmium-zinc-thelluride camera in detecting significant coronary artery disease (CAD) in patients with atrial fibrillation (AF). Methods and results Seventy-four subjects with AF submitted to stress-rest MPI and coronary angiography were consecutively enrolled.One hundred and forty-eight patients in sinus rhythm, matched for age, sex, and type of stress-test protocol and with known coronary anatomy served as controls. The summed difference score, as measure of reversible myocardial ischaemia,was calculated. A coronary stenosis ≥70% was considered significant. The prevalence of significant CAD did not differ betweenAFpatients and controls. At receiving operating characteristic analysis MPI showed relevant accuracy in unmasking the presence of significantCADboth in AFand in control patients (areas under the curve 0.71 vs. 0.80, P for difference: 0.212).However, after stratifying patients according to the stress protocol, a significant interaction between the presence of AF and MPI diagnostic power was evident. While in the case of a vasodilator stress-test MPI diagnostic accuracy remained high in both groups of patients (P for difference: 0.664), in those submitted to an exercise stress-test the diagnostic power of MPI was significantly lower in the presence of AF (P for difference: 0.039), because of a lower specificity. Interestingly, at multivariate analysis, a lower exercise duration (P = 0.017) was the major predictor of reduced MPI specificity. Conclusion The presence of AF impairs MPI accuracy on the detection significant CAD. This effect was only apparent in the case of an exercise stress-test, while disappeared in patients submitted to vasodilator stress.
2015
Gimelli, A.; Liga, R.; Startari, U.; Giorgetti, A.; Pieraccini, L.; Marzullo, P.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1084214
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact