Background: An interaction between coronary anatomy, myocardial perfusion, and left ventricular (LV) functional parameters in the development of mechanical LV dyssynchrony (LVD) has been suggested. This study examined the correlates of LVD in a large sample size of patients with known or suspected coronary artery disease (CAD) using cadmium-zinc-telluride camera. Methods: Six-hundred and fifty-seven consecutive patients who underwent myocardial perfusion imaging (MPI) and coronary angiography were included. Coronary stenosis >70% was considered significant. LV perfusion and functional parameters were computed from MPI images. The presence of significant LVD was evaluated by phase standard deviation and histogram bandwidth. Results: 415/657 (63%) patients had significant CAD. LVD was present in 247 (38%) patients and was associated with the presence of a higher CAD burden (P < .001), more impaired measures of LV perfusion (P < .001), contractile function (P < .001), and larger LV volumes (P < .001). By multivariate analysis, the LV end-systolic volume index (P < .001) and ischemic burden (P < .001) were the strongest predictors of LVD independent of CAD extent and LV systolic dysfunction. Conclusions: LVD is frequent in patients undergoing MPI for suspected or known CAD. Its presence is independent of CAD burden and LV systolic dysfunction, but is dependent on the presence of myocardial perfusion abnormalities and LV end-systolic volume.

Determinants of left ventricular mechanical dyssynchrony in patients submitted to myocardial perfusion imaging: A cardiac CZT study

Liga R.
Co-primo
;
Giorgetti A.;
2016-01-01

Abstract

Background: An interaction between coronary anatomy, myocardial perfusion, and left ventricular (LV) functional parameters in the development of mechanical LV dyssynchrony (LVD) has been suggested. This study examined the correlates of LVD in a large sample size of patients with known or suspected coronary artery disease (CAD) using cadmium-zinc-telluride camera. Methods: Six-hundred and fifty-seven consecutive patients who underwent myocardial perfusion imaging (MPI) and coronary angiography were included. Coronary stenosis >70% was considered significant. LV perfusion and functional parameters were computed from MPI images. The presence of significant LVD was evaluated by phase standard deviation and histogram bandwidth. Results: 415/657 (63%) patients had significant CAD. LVD was present in 247 (38%) patients and was associated with the presence of a higher CAD burden (P < .001), more impaired measures of LV perfusion (P < .001), contractile function (P < .001), and larger LV volumes (P < .001). By multivariate analysis, the LV end-systolic volume index (P < .001) and ischemic burden (P < .001) were the strongest predictors of LVD independent of CAD extent and LV systolic dysfunction. Conclusions: LVD is frequent in patients undergoing MPI for suspected or known CAD. Its presence is independent of CAD burden and LV systolic dysfunction, but is dependent on the presence of myocardial perfusion abnormalities and LV end-systolic volume.
2016
Gimelli, A.; Liga, R.; Giorgetti, A.; Favilli, B.; Pasanisi, E. M.; Marzullo, P.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1084830
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 21
social impact