The present paper illustrates the setup and the preliminary results of an experimental investigation of cavitation flow instabilities carried out by means of a high-speed camera on a three-bladed inducer in the cavitating pump rotordynamic test facility (CPRTF) at Alta S.p.A. The brightness thresholding technique adopted/or cavitation recognition is described and implemented in a semi-automatic algorithm. In order to test the capabilities of the algorithm, the mean frontal cavitating area has been computed under different operating conditions. The tip cavity length has also been evaluated as a function of time. Inlet pressure signal and video acquisitions have been synchronized in order to analyze possible cavitation fluid-dynamic instabilities both optically and by means of pressure fluctuation analysis. Fourier analysis showed the occurrence of a cavity length oscillation at a frequency of 14.7 Hz, which corresponds to the frequency of the rotating stall instability dete...

Setup of a High-Speed Optical System for the Characterization of Flow Instabilities Generated by Cavitation

D'AGOSTINO, LUCA
2007-01-01

Abstract

The present paper illustrates the setup and the preliminary results of an experimental investigation of cavitation flow instabilities carried out by means of a high-speed camera on a three-bladed inducer in the cavitating pump rotordynamic test facility (CPRTF) at Alta S.p.A. The brightness thresholding technique adopted/or cavitation recognition is described and implemented in a semi-automatic algorithm. In order to test the capabilities of the algorithm, the mean frontal cavitating area has been computed under different operating conditions. The tip cavity length has also been evaluated as a function of time. Inlet pressure signal and video acquisitions have been synchronized in order to analyze possible cavitation fluid-dynamic instabilities both optically and by means of pressure fluctuation analysis. Fourier analysis showed the occurrence of a cavity length oscillation at a frequency of 14.7 Hz, which corresponds to the frequency of the rotating stall instability dete...
2007
Cervone, A; Bramanti, C; Torre, L; Fotino, D; D'Agostino, Luca
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/110087
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 16
social impact