The parameters derived from reservoir-excess pressure analysis have prognostic utility in several populations. However, evidence in type 2 diabetes (T2DM) remains scarce. We determined if these parameters were associated with T2DM and whether they would predict cardiovascular events in individuals with T2DM. We studied 306 people with T2DM with cardiovascular disease (CVD; DMCVD, 70.4±7.8 years), 348 people with T2DM but without CVD (diabetes mellitus, 67.7±8.4 years), and 178 people without T2DM or CVD (control group [CTRL], 67.2±8.9 years). Reservoir-excess pressure analysis-derived parameters, including reservoir pressure integral, peak reservoir pressure, excess pressure integral, systolic rate constant, and diastolic rate constant, were obtained by radial artery tonometry. Reservoir pressure integral was lower in DMCVD diabetes mellitus and than CTRL. Peak reservoir pressure was lower, and excess pressure integral was greater in DMCVD diabetes mellitus than and CTRL. Systolic rate constant was lower in a stepwise manner among groups (DMCVD< diabetes mellitus

Reservoir-Excess Pressure Parameters Independently Predicts Cardiovascular Events in Individuals With Type 2 Diabetes

Palombo, Carlo
Conceptualization
;
2021-01-01

Abstract

The parameters derived from reservoir-excess pressure analysis have prognostic utility in several populations. However, evidence in type 2 diabetes (T2DM) remains scarce. We determined if these parameters were associated with T2DM and whether they would predict cardiovascular events in individuals with T2DM. We studied 306 people with T2DM with cardiovascular disease (CVD; DMCVD, 70.4±7.8 years), 348 people with T2DM but without CVD (diabetes mellitus, 67.7±8.4 years), and 178 people without T2DM or CVD (control group [CTRL], 67.2±8.9 years). Reservoir-excess pressure analysis-derived parameters, including reservoir pressure integral, peak reservoir pressure, excess pressure integral, systolic rate constant, and diastolic rate constant, were obtained by radial artery tonometry. Reservoir pressure integral was lower in DMCVD diabetes mellitus and than CTRL. Peak reservoir pressure was lower, and excess pressure integral was greater in DMCVD diabetes mellitus than and CTRL. Systolic rate constant was lower in a stepwise manner among groups (DMCVD< diabetes mellitus
2021
Aizawa, Kunihiko; Casanova, Francesco; Gates, Phillip E; Mawson, David M; Gooding, Kim M; Strain, W David; Östling, Gerd; Nilsson, Jan; Khan, Faisel; ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1101296
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact