Introduction: In patients with short nipple to inframammary fold (N-IMF) distance, as in tuberous breast, the cohesivity and gel distribution of shaped implants work as a controlled tissue expander, progressively adapting the tissues to the implant’s shape. This phenomenon translates into a gradual increase of the N-IMF distance over time, but the true extent to which this occurs has not been quantified to date. This study aims to quantify the postoperative variation of the N-IMF distance in tuberous breast treated with shaped cohesive silicone breast implants. Methods: We did a retrospective review of a prospective maintained database of all consecutive patients with bilateral Groulleau I and II tuberous breasts who underwent primary breast augmentation between April 2017 and May 2018 at our institution. To quantify the lower mammary pole's morphological changes, we evaluated the N-IMF distance under maximal stretch as an endpoint. We recorded this value at time 0 (preoperative), immediate post-op (equivalent to the distance planned preoperatively) and at month 1, month 6 and 1-year post-op. Then we calculated the average N-IMF distance variation of our sample of patients with a 99% interval of confidence for each breast obtained. Comparisons were performed using the Sign test and the Mann-Whitney U test. Results: The average implant weight was 353g (range 290-450; SD ±46.147). Of the 54 breasts analyzed, the immediate post-op N-IMF distance was on average 2.43 cm longer than the preop IMF with a 99% confidence interval between 2.01 and 2.86 and SD of ±1.22. The mean difference between the preop N-IMF distance and after 1, 6 and 12 months was respectively 2.78 cm (SD,1.56) (99% CI, 2.24–3.34), 3.08 cm (SD, 1.57) (99% CI, 2.53–3.64), and 3.36 (1.55) (99% CI, 2.82–3.91) Comparing immediate postoperative nipple to inframammary fold distance (N-IMF) to the 1, 6 and 12 months N-IMF values, an average of 4.23% (CI 1.3–7.16), 7.74% (CI 4.25–11.23) and 10.84% (CI 7.21–14.49) of skin length, was gained respectively. According to implants’ weight, subgroup analysis showed that implants > 400 g were associated with significantly higher N-IMF distance increase (p <0.05) compared to implants < 400 g. Conclusions: Our findings suggest that a significant progressive postoperative increase in N-IMF distance should be expected in all cases of tuberous breast augmentation with anatomical implants over a 1 year period. This aspect may have an important implication on the IMF incision and the new fold position preoperative planning.

Quantitative Analysis of Nipple to Inframammary Fold Distance Variation in Tuberous Breast Augmentation: Is there a Progressive Lower Pole Expansion?

Cigna E.;
2021-01-01

Abstract

Introduction: In patients with short nipple to inframammary fold (N-IMF) distance, as in tuberous breast, the cohesivity and gel distribution of shaped implants work as a controlled tissue expander, progressively adapting the tissues to the implant’s shape. This phenomenon translates into a gradual increase of the N-IMF distance over time, but the true extent to which this occurs has not been quantified to date. This study aims to quantify the postoperative variation of the N-IMF distance in tuberous breast treated with shaped cohesive silicone breast implants. Methods: We did a retrospective review of a prospective maintained database of all consecutive patients with bilateral Groulleau I and II tuberous breasts who underwent primary breast augmentation between April 2017 and May 2018 at our institution. To quantify the lower mammary pole's morphological changes, we evaluated the N-IMF distance under maximal stretch as an endpoint. We recorded this value at time 0 (preoperative), immediate post-op (equivalent to the distance planned preoperatively) and at month 1, month 6 and 1-year post-op. Then we calculated the average N-IMF distance variation of our sample of patients with a 99% interval of confidence for each breast obtained. Comparisons were performed using the Sign test and the Mann-Whitney U test. Results: The average implant weight was 353g (range 290-450; SD ±46.147). Of the 54 breasts analyzed, the immediate post-op N-IMF distance was on average 2.43 cm longer than the preop IMF with a 99% confidence interval between 2.01 and 2.86 and SD of ±1.22. The mean difference between the preop N-IMF distance and after 1, 6 and 12 months was respectively 2.78 cm (SD,1.56) (99% CI, 2.24–3.34), 3.08 cm (SD, 1.57) (99% CI, 2.53–3.64), and 3.36 (1.55) (99% CI, 2.82–3.91) Comparing immediate postoperative nipple to inframammary fold distance (N-IMF) to the 1, 6 and 12 months N-IMF values, an average of 4.23% (CI 1.3–7.16), 7.74% (CI 4.25–11.23) and 10.84% (CI 7.21–14.49) of skin length, was gained respectively. According to implants’ weight, subgroup analysis showed that implants > 400 g were associated with significantly higher N-IMF distance increase (p <0.05) compared to implants < 400 g. Conclusions: Our findings suggest that a significant progressive postoperative increase in N-IMF distance should be expected in all cases of tuberous breast augmentation with anatomical implants over a 1 year period. This aspect may have an important implication on the IMF incision and the new fold position preoperative planning.
2021
Avvedimento, S.; Montemurro, P.; Cigna, E.; Guastafierro, A.; Cagli, B.; Santorelli, A.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1109509
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact