Background: This study aimed to evaluate a Multiple Stent Delivery System for provisional focal stenting of the femoropopliteal artery. Patient and methods: The LOCOMOTIVE EXTENDED study (Multi-LOC for flOw liMiting Outcomes after plain old balloon angioplasty and/or drug-coated balloon Treatment in the infrainguinal position with the objectIVE to implant multiple stent segments) is a prospective, single-arm, multicentre observational study. The Multi-LOC Multiple Stent Delivery System (B.Braun, Melsungen, Germany) was used for provisional focal stenting of the femoropopliteal artery. We enrolled 357 patients with 449 femoropopliteal lesions; all had flow-limiting dissections or recoil following angioplasty. Eligibility included Rutherford classification 2 to 5 with a de novo or non-stented restenotic femoropopliteal lesion undergoing plain balloon or drug-coated balloon angioplasty. The 6- A nd 12-month efficacy endpoints encompassed target lesion revascularisation and primary patency rates. Results: The mean patient age was 71 ± 10 years. The mean lesion length was 16.0 ± 9.7 cm; 44.5% were TASC II C/D lesions and 31.4% were chronic total occlusions. By operator choice, 45% of the patients underwent drugcoated balloon angioplasty. On average, 4.0 stents (each 13 mm long) were placed in each lesion, resulting in a scaffolding proportion of 56% of the total lesion length with a technical success rate of 98.3%. At 6 and 12 months, the freedom from clinically driven target lesion revascularisation was 95.5% and 88.7% and the primary patency rates were 88.7% and 82.3%, respectively. At 12 months, significant improvements were noted in Rutherford categories and ankle-brachial indices. In multiple regression analyses, both diabetes mellitus and no distal run-off vessel showed a trend toward worse TLR, while other factors such as DCB predilation or the lesion length were not predictive. Conclusions: The LOCOMOTIVE EXTENDED study demonstrated the safety and efficacy of the Multi-LOC stent system for focal provisional stenting of complex femoropopliteal lesions.

Provisional focal stenting of complex femoropopliteal lesions using the Multi-LOC multiple stent delivery system – 12-month results from the LOCOMOTIVE EXTENDED study

Troisi N.
Membro del Collaboration Group
;
2021-01-01

Abstract

Background: This study aimed to evaluate a Multiple Stent Delivery System for provisional focal stenting of the femoropopliteal artery. Patient and methods: The LOCOMOTIVE EXTENDED study (Multi-LOC for flOw liMiting Outcomes after plain old balloon angioplasty and/or drug-coated balloon Treatment in the infrainguinal position with the objectIVE to implant multiple stent segments) is a prospective, single-arm, multicentre observational study. The Multi-LOC Multiple Stent Delivery System (B.Braun, Melsungen, Germany) was used for provisional focal stenting of the femoropopliteal artery. We enrolled 357 patients with 449 femoropopliteal lesions; all had flow-limiting dissections or recoil following angioplasty. Eligibility included Rutherford classification 2 to 5 with a de novo or non-stented restenotic femoropopliteal lesion undergoing plain balloon or drug-coated balloon angioplasty. The 6- A nd 12-month efficacy endpoints encompassed target lesion revascularisation and primary patency rates. Results: The mean patient age was 71 ± 10 years. The mean lesion length was 16.0 ± 9.7 cm; 44.5% were TASC II C/D lesions and 31.4% were chronic total occlusions. By operator choice, 45% of the patients underwent drugcoated balloon angioplasty. On average, 4.0 stents (each 13 mm long) were placed in each lesion, resulting in a scaffolding proportion of 56% of the total lesion length with a technical success rate of 98.3%. At 6 and 12 months, the freedom from clinically driven target lesion revascularisation was 95.5% and 88.7% and the primary patency rates were 88.7% and 82.3%, respectively. At 12 months, significant improvements were noted in Rutherford categories and ankle-brachial indices. In multiple regression analyses, both diabetes mellitus and no distal run-off vessel showed a trend toward worse TLR, while other factors such as DCB predilation or the lesion length were not predictive. Conclusions: The LOCOMOTIVE EXTENDED study demonstrated the safety and efficacy of the Multi-LOC stent system for focal provisional stenting of complex femoropopliteal lesions.
2021
Amendt, K.; Zeller, T.; Proczka, R.; Beschorner, U.; Troisi, N.; Waliszewski, M.; Langhoff, R.; Krankenberg, H.; Hansch, A.; Krcmar, T.; Vidjak, V.; N...espandi
File in questo prodotto:
File Dimensione Formato  
Vasa articolo pubblicato.pdf

accesso aperto

Tipologia: Versione finale editoriale
Licenza: Creative commons
Dimensione 263.52 kB
Formato Adobe PDF
263.52 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1116326
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact