Purpose: The aim of the study was to compare the long-term clinical and electrical performance of Micra leadless pacemaker with transvenous single-chamber pacemaker (TV-VVI PM) in a high-volume centre for transvenous lead extraction (TLE). Methods: One-hundred patients (group 1) undergoing Micra implant were matched with 100 patients undergoing TV-VVI PM implant (group 2) by age, sex, left ventricular systolic ejection fraction and previous TLE. Results: The implant procedure was successful in all patients. In group 1, the procedure duration was lower than in group 2 (43.86 ± 22.38 vs 58.38 ± 17.85 min, p < 0.001), while the fluoroscopy time was longer (12.25 ± 6.84 vs 5.32 ± 4.42 min, p < 0.001). There was no difference about the rate of septal implant at the right ventricle (76% vs 86%, p = 0.10). Patients were followed-up for a median of 12 months. No acute and chronic procedure-related complication was observed in group 1, while we reported acute complications in seven patients (7%, p = 0.02) and long-term complications in three patients (3%, p = 0.24), needing for a system revision in 6 cases (6%, p = 0.038), in group 2. One systemic infection occurred in TV-VVI PM group. Electrical measurements were stable during follow-up in both groups, with a longer estimated battery life in group 1 (mean delivered energy at threshold at discharge: 0.14 ± 0.21 vs 0.26 ± 0.22 μJ, p < 0.001). Conclusion: Micra pacemaker implant is a safe and effective procedure, with a lower rate of acute complications and system revisions compared with TV-VVI PM, even in a real-life setting including patients who underwent TLE.

Comparison between leadless and transvenous single-chamber pacemaker therapy in a referral centre for lead extraction

Zucchelli G.;Tolve S.;Barletta V.;Di Cori A.;Parollo M.;Della Tommasina V.;Giannotti Santoro M.;Cellamaro T.;Segreti L.;Paperini L.;Soldati E.;Bongiorni M. G.
2021-01-01

Abstract

Purpose: The aim of the study was to compare the long-term clinical and electrical performance of Micra leadless pacemaker with transvenous single-chamber pacemaker (TV-VVI PM) in a high-volume centre for transvenous lead extraction (TLE). Methods: One-hundred patients (group 1) undergoing Micra implant were matched with 100 patients undergoing TV-VVI PM implant (group 2) by age, sex, left ventricular systolic ejection fraction and previous TLE. Results: The implant procedure was successful in all patients. In group 1, the procedure duration was lower than in group 2 (43.86 ± 22.38 vs 58.38 ± 17.85 min, p < 0.001), while the fluoroscopy time was longer (12.25 ± 6.84 vs 5.32 ± 4.42 min, p < 0.001). There was no difference about the rate of septal implant at the right ventricle (76% vs 86%, p = 0.10). Patients were followed-up for a median of 12 months. No acute and chronic procedure-related complication was observed in group 1, while we reported acute complications in seven patients (7%, p = 0.02) and long-term complications in three patients (3%, p = 0.24), needing for a system revision in 6 cases (6%, p = 0.038), in group 2. One systemic infection occurred in TV-VVI PM group. Electrical measurements were stable during follow-up in both groups, with a longer estimated battery life in group 1 (mean delivered energy at threshold at discharge: 0.14 ± 0.21 vs 0.26 ± 0.22 μJ, p < 0.001). Conclusion: Micra pacemaker implant is a safe and effective procedure, with a lower rate of acute complications and system revisions compared with TV-VVI PM, even in a real-life setting including patients who underwent TLE.
2021
Zucchelli, G.; Tolve, S.; Barletta, V.; Di Cori, A.; Parollo, M.; De Lucia, R.; Della Tommasina, V.; Giannotti Santoro, M.; Viani, S.; Cellamaro, T.; Segreti, L.; Paperini, L.; Soldati, E.; Bongiorni, M. G.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1120206
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact