Objective The purpose of this study was to compare the outcomes obtained with Endurant stent graft in the early and midterm period in the treatment of patients with narrow aortic bifurcation vs patients with standard aortic bifurcation. Methods Data were prospectively collected from 817 patients with abdominal aortic aneurysm treated between November 2007 and August 2014 with the Endurant stent graft at our center. There were 87 patients (10.6%) with a narrow aortic bifurcation (≤20 mm; NA group). The remaining 730 patients (89.4%) had a standard aortic bifurcation (SA group). Early and estimated 3-year outcomes were evaluated in these patients in terms of survival, freedom from any device-related reinterventions, and freedom from graft thrombosis. Univariate and multivariate analyses in the NA group were performed to detect possible predictors for poor outcomes. Results The two groups were similar in terms of demographics, preoperative diagnostic assessment, and intraoperative data. In 211 of 817 patients (25.8%), an adjunctive iliac limb stenting by balloon-expanding stents was performed. Overall, 41 patients in the NA group (47.1%) underwent iliac limb stenting, whereas an iliac stent was implanted in just 170 patients (23.3%) in the SA group (P <.001). The mean follow-up was 16.3 months (range, 1-73 months). The estimated 3-year survival rate was similar between the two groups (87.2% in the NA group vs 80.8% in the SA group; P =.84). Furthermore, the estimated freedom from any device-related reinterventions was 92.9% in the NA group and 85.5% in the SA group (P =.1). Finally, the estimated 3-year freedom from graft thrombosis was 96.9% in the NA group and 94.8% in the SA group (P =.79). In the NA group at univariate and multivariate analyses, none of the examined preoperative or intraoperative factors were independent predictors of poor outcomes. Conclusions Use of bifurcated Endurant stent graft, combined in almost half of the patients with narrow aortic bifurcation with additional aortoiliac stent placement, is feasible and safe. Early and midterm outcomes are similar to those obtained in non-narrow aortic bifurcation.

Outcomes of Endurant stent graft in narrow aortic bifurcation

Troisi N.
Primo
Writing – Original Draft Preparation
;
2016-01-01

Abstract

Objective The purpose of this study was to compare the outcomes obtained with Endurant stent graft in the early and midterm period in the treatment of patients with narrow aortic bifurcation vs patients with standard aortic bifurcation. Methods Data were prospectively collected from 817 patients with abdominal aortic aneurysm treated between November 2007 and August 2014 with the Endurant stent graft at our center. There were 87 patients (10.6%) with a narrow aortic bifurcation (≤20 mm; NA group). The remaining 730 patients (89.4%) had a standard aortic bifurcation (SA group). Early and estimated 3-year outcomes were evaluated in these patients in terms of survival, freedom from any device-related reinterventions, and freedom from graft thrombosis. Univariate and multivariate analyses in the NA group were performed to detect possible predictors for poor outcomes. Results The two groups were similar in terms of demographics, preoperative diagnostic assessment, and intraoperative data. In 211 of 817 patients (25.8%), an adjunctive iliac limb stenting by balloon-expanding stents was performed. Overall, 41 patients in the NA group (47.1%) underwent iliac limb stenting, whereas an iliac stent was implanted in just 170 patients (23.3%) in the SA group (P <.001). The mean follow-up was 16.3 months (range, 1-73 months). The estimated 3-year survival rate was similar between the two groups (87.2% in the NA group vs 80.8% in the SA group; P =.84). Furthermore, the estimated freedom from any device-related reinterventions was 92.9% in the NA group and 85.5% in the SA group (P =.1). Finally, the estimated 3-year freedom from graft thrombosis was 96.9% in the NA group and 94.8% in the SA group (P =.79). In the NA group at univariate and multivariate analyses, none of the examined preoperative or intraoperative factors were independent predictors of poor outcomes. Conclusions Use of bifurcated Endurant stent graft, combined in almost half of the patients with narrow aortic bifurcation with additional aortoiliac stent placement, is feasible and safe. Early and midterm outcomes are similar to those obtained in non-narrow aortic bifurcation.
2016
Troisi, N.; Donas, K. P.; Weiss, K.; Michelagnoli, S.; Torsello, G.; Bisdas, T.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1123336
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 18
social impact