Heart failure (HF) is the main cause of mortality worldwide, particularly in the elderly. N-terminal pro-brain natriuretic peptide (NT-proBNP) is the gold standard biomarker for HF diagnosis and therapy monitoring. It is determined in blood samples by the immunochemical methods generally adopted by most laboratories. Saliva analysis is a powerful tool for clinical applications, mainly due to its non-invasive and less risky sampling. This study describes a validated analytical procedure for NT-proBNP determination in saliva samples using a commercial Enzyme-Linked Immuno-Sorbent Assay. Linearity, matrix effect, sensitivity, recovery and assay-precision were evaluated. The analytical approach showed a linear behaviour of the signal throughout the concentrations tested, with a minimum detectable dose of 1 pg/mL, a satisfactory NT-proBNP recovery (95–110%), and acceptable precision (coefficient of variation ≤ 10%). Short-term (3 weeks) and long-term (5 months) stability of NT-proBNP in saliva samples under the storage conditions most frequently used in clinical laboratories (4, − 20, and − 80 °C) was also investigated and showed that the optimal storage conditions were at − 20 °C for up to 2.5 months. Finally, the method was tested for the determination of NT-proBNP in saliva samples collected from ten hospitalized acute HF patients. Preliminary results indicate a decrease in NT-proBNP in saliva from admission to discharge, thus suggesting that this procedure is an effective saliva-based point-of-care device for HF monitoring.

Determination and stability of N-terminal pro-brain natriuretic peptide in saliva samples for monitoring heart failure

Salvo P.;Ghimenti S.;Franzini M.;Biagini D.;Trivella M. G.;Di Francesco F.;Paolicchi A.;Fuoco R.;Lomonaco T.
2021-01-01

Abstract

Heart failure (HF) is the main cause of mortality worldwide, particularly in the elderly. N-terminal pro-brain natriuretic peptide (NT-proBNP) is the gold standard biomarker for HF diagnosis and therapy monitoring. It is determined in blood samples by the immunochemical methods generally adopted by most laboratories. Saliva analysis is a powerful tool for clinical applications, mainly due to its non-invasive and less risky sampling. This study describes a validated analytical procedure for NT-proBNP determination in saliva samples using a commercial Enzyme-Linked Immuno-Sorbent Assay. Linearity, matrix effect, sensitivity, recovery and assay-precision were evaluated. The analytical approach showed a linear behaviour of the signal throughout the concentrations tested, with a minimum detectable dose of 1 pg/mL, a satisfactory NT-proBNP recovery (95–110%), and acceptable precision (coefficient of variation ≤ 10%). Short-term (3 weeks) and long-term (5 months) stability of NT-proBNP in saliva samples under the storage conditions most frequently used in clinical laboratories (4, − 20, and − 80 °C) was also investigated and showed that the optimal storage conditions were at − 20 °C for up to 2.5 months. Finally, the method was tested for the determination of NT-proBNP in saliva samples collected from ten hospitalized acute HF patients. Preliminary results indicate a decrease in NT-proBNP in saliva from admission to discharge, thus suggesting that this procedure is an effective saliva-based point-of-care device for HF monitoring.
2021
Bellagambi, F. G.; Petersen, C.; Salvo, P.; Ghimenti, S.; Franzini, M.; Biagini, D.; Hangouet, M.; Trivella, M. G.; Di Francesco, F.; Paolicchi, A.; Errachid, A.; Fuoco, R.; Lomonaco, T.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1126548
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 17
social impact