Few data are available on cardiac resynchronization therapy (CRT) after coronary sinus (CS) lead extraction. We aimed to evaluate the feasibility and mid-term outcome of transvenous CS lead reimplantation in a tertiary referral centre.We enrolled all patients who were referred to our hospital for CS lead removal from December 2000 through to May 2009 and were transvenously reimplanted with a CRT system before June 2009. One-year follow-up was performed to evaluate the incidence of infections, malfunctions, and mortality. We studied 113 consecutive patients undergoing successful CS lead extraction; 90 patients (75 male, mean age 69.2, range 3584) underwent CS lead reimplantation (success rate: 95.6; right-sided approach: 64.4). In these patients, cardiac device infection was the usual indication for extraction (74.4) and the subsequent reimplantation was performed after a median time of 3 days. The coronary sinus lead was usually positioned in the left ventricular (LV) postero-lateral region (62.2); two procedures were required in two cases (2.2). Balloon angioplasty was necessary for two patients (failure in one), whereas for the others we used a conventional implant technique. During follow-up, we observed four cases (4.4) of local infection and six cases (6.7) of system malfunction, requiring reintervention (two cases during the same hospitalization). One-year mortality was 5.5.Left ventricular lead reimplantation is in our experience an effective and safe procedure, also in the case of right-sided approach. During follow-up, 1-year mortality was particularly low, whereas overall infection rate was higher than first implant procedures.

Cardiac resynchronization therapy after coronary sinus lead extraction: feasibility and mid-term outcome of transvenous reimplantation in a tertiary referral centre

Zucchelli, Giulio;Bongiorni, Maria Grazia;Di Cori, Andrea;Solarino, Gianluca;Fabiani, Iacopo;Segreti, Luca;Coluccia, Giovanni;Paperini, Luca
2012-01-01

Abstract

Few data are available on cardiac resynchronization therapy (CRT) after coronary sinus (CS) lead extraction. We aimed to evaluate the feasibility and mid-term outcome of transvenous CS lead reimplantation in a tertiary referral centre.We enrolled all patients who were referred to our hospital for CS lead removal from December 2000 through to May 2009 and were transvenously reimplanted with a CRT system before June 2009. One-year follow-up was performed to evaluate the incidence of infections, malfunctions, and mortality. We studied 113 consecutive patients undergoing successful CS lead extraction; 90 patients (75 male, mean age 69.2, range 3584) underwent CS lead reimplantation (success rate: 95.6; right-sided approach: 64.4). In these patients, cardiac device infection was the usual indication for extraction (74.4) and the subsequent reimplantation was performed after a median time of 3 days. The coronary sinus lead was usually positioned in the left ventricular (LV) postero-lateral region (62.2); two procedures were required in two cases (2.2). Balloon angioplasty was necessary for two patients (failure in one), whereas for the others we used a conventional implant technique. During follow-up, we observed four cases (4.4) of local infection and six cases (6.7) of system malfunction, requiring reintervention (two cases during the same hospitalization). One-year mortality was 5.5.Left ventricular lead reimplantation is in our experience an effective and safe procedure, also in the case of right-sided approach. During follow-up, 1-year mortality was particularly low, whereas overall infection rate was higher than first implant procedures.
2012
Zucchelli, Giulio; Bongiorni, Maria Grazia; Di Cori, Andrea; Soldati, Ezio; Solarino, Gianluca; Fabiani, Iacopo; Segreti, Luca; De Lucia, Raffaele; Viani, Stefano; Coluccia, Giovanni; Paperini, Luca
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1147708
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact