Background: The aim of this study was to evaluate procedural outcomes of coronary sinus (CS) lead extraction, focusing on predictors and need for mechanical dilatation (MD) in the event that manual traction (MT) is ineffective.Methods: The study assessed results in 145 consecutive patients (age 69 +/- 10 years; 121 men)-a total of 147 CS pacing leads-who underwent transvenous CS lead removal between January 2000 and March 2010.Results: All leads but one (99%) (implantation time 29 +/- 25 months) were successfully removed. MT was effective in 103 (70%), and MD was necessary in the remaining 44 (30%) procedures. In multivariate analyses, unipolar design (odds ratio [OR] 3.22, 95% confidence interval [CI] 1.43-7.7; P = 0.005) and noninfective indication (OR 4.8, 95% CI 1.8-13, P = 0.002) were independent predictors for MD (P < 0.0001), with a predictive trend for prior cardiac surgery (OR 2.2, 95% CI 0.98-5.26; P = 0.06). Five (3.4%) complex procedures required a transfemoral vein approach (TFA) or repeat procedure. No deaths occurred, and there was one major complication (0.7%), cardiac tamponade, after MT. No complication predictors were identified.Conclusions: CS leads were safely and effectively removed in nearly all patients, and 70% were removed with MT alone; 30% required MD. Preoperative predictors suggesting the need for MD or TFA were noninfective indication and unipolar lead design. Complications were rare, and there was no predictable pattern among MT or MD removal techniques. (PACE 2012; 35:215-222)

Large, single-center experience in transvenous coronary sinus lead extraction: procedural outcomes and predictors for mechanical dilatation

di Cori, Andrea
Primo
;
Bongiorni, Maria Grazia;Zucchelli, Giulio;Segreti, Luca;Paperini, Luca;
2012-01-01

Abstract

Background: The aim of this study was to evaluate procedural outcomes of coronary sinus (CS) lead extraction, focusing on predictors and need for mechanical dilatation (MD) in the event that manual traction (MT) is ineffective.Methods: The study assessed results in 145 consecutive patients (age 69 +/- 10 years; 121 men)-a total of 147 CS pacing leads-who underwent transvenous CS lead removal between January 2000 and March 2010.Results: All leads but one (99%) (implantation time 29 +/- 25 months) were successfully removed. MT was effective in 103 (70%), and MD was necessary in the remaining 44 (30%) procedures. In multivariate analyses, unipolar design (odds ratio [OR] 3.22, 95% confidence interval [CI] 1.43-7.7; P = 0.005) and noninfective indication (OR 4.8, 95% CI 1.8-13, P = 0.002) were independent predictors for MD (P < 0.0001), with a predictive trend for prior cardiac surgery (OR 2.2, 95% CI 0.98-5.26; P = 0.06). Five (3.4%) complex procedures required a transfemoral vein approach (TFA) or repeat procedure. No deaths occurred, and there was one major complication (0.7%), cardiac tamponade, after MT. No complication predictors were identified.Conclusions: CS leads were safely and effectively removed in nearly all patients, and 70% were removed with MT alone; 30% required MD. Preoperative predictors suggesting the need for MD or TFA were noninfective indication and unipolar lead design. Complications were rare, and there was no predictable pattern among MT or MD removal techniques. (PACE 2012; 35:215-222)
2012
di Cori, Andrea; Bongiorni, Maria Grazia; Zucchelli, Giulio; Segreti, Luca; Viani, Stefano; de Lucia, Raffaele; Paperini, Luca; Soldati, Ezio
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1159414
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 35
social impact