In this paper, a microwave imaging method able to inspect three-dimensional configurations is proposed. The approach is developed in Lp Banach spaces, and allows to suitably face the ill-posedness of the considered full vector inverse scattering problem. The assumed nonconventional spaces require several modifications in the original inexact-Newton scheme, which give rise to a significant improvement in reducing the oversmoothing effects in the reconstructed distributions of the dielectric properties of the targets. The proposed approach is discussed in details and validated by using both numerical simulations and real data.
Three-dimensional microwave imaging in Lp Banach spaces: Numerical and experimental results
Tavanti, Emanuele
2018-01-01
Abstract
In this paper, a microwave imaging method able to inspect three-dimensional configurations is proposed. The approach is developed in Lp Banach spaces, and allows to suitably face the ill-posedness of the considered full vector inverse scattering problem. The assumed nonconventional spaces require several modifications in the original inexact-Newton scheme, which give rise to a significant improvement in reducing the oversmoothing effects in the reconstructed distributions of the dielectric properties of the targets. The proposed approach is discussed in details and validated by using both numerical simulations and real data.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.