We demonstrate that a negative feedback between vapor pressure and condensation rate may be established in two-phase systems during vapor compression with rates of practical importance. As a result, dynamic condensation blocking occurs. The effect is studied numerically in the case of filling a no-vent insulated tank by liquid hydrogen. It is shown that the filling dynamics quite sensitively depends on the filling rate, and for sufficiently fast filling rates consist of a fast stage dominated by gas compression and a slow stage governed by heat conduction in the liquid.
Dynamic condensation blocking in cryogenic refueling
C. B. Muratov
2008-01-01
Abstract
We demonstrate that a negative feedback between vapor pressure and condensation rate may be established in two-phase systems during vapor compression with rates of practical importance. As a result, dynamic condensation blocking occurs. The effect is studied numerically in the case of filling a no-vent insulated tank by liquid hydrogen. It is shown that the filling dynamics quite sensitively depends on the filling rate, and for sufficiently fast filling rates consist of a fast stage dominated by gas compression and a slow stage governed by heat conduction in the liquid.File in questo prodotto:
Non ci sono file associati a questo prodotto.