The aim of this paper is the investigation of cold energy recovery of liquefied natural gas (LNG) in regasification terminals achievable through direct expansion techniques. After an overview of the state of the art related to the LNG system and the technologies proposed for power recovery, multi-pressure direct expansion solutions with internal heat recovery (multi-pressure DE) are analysed. The purpose is to identify the highest level of recoverable energy and the optimal design parameters, considering technological constraints such as pressure and minimum end-expansion temperature. The multi-pressure DE solutions prove to be innovative power recovery methods because, with a relatively low use of seawater, it is possible to save regasified LNG and generate electrical power, valorising the energy invested in liquefaction. An estimate of recoverable power in operating terminals is carried out. Configurations with cryogenic or non-cryogenic turboexpanders are discussed. Using the proposed solution with non-cryogenic turboexpander and distribution pressure of 3.5 MPa, 56 kJ for each kg of LNG can be produced, which can become more than 150 kJ/kg with cryogenic turboexpanders. For long-distance distribution, cryogenic multi-pressure DE cycles can recover around 100-120 kJ per kg of LNG. The presented techniques can allow recovery of up to and over 30% of the maximum specific work available in LNG regasification.

Optimal design of direct expansion systems for electricity production by LNG cold energy recovery

Franco A.
;
Giovannini C.
2023-01-01

Abstract

The aim of this paper is the investigation of cold energy recovery of liquefied natural gas (LNG) in regasification terminals achievable through direct expansion techniques. After an overview of the state of the art related to the LNG system and the technologies proposed for power recovery, multi-pressure direct expansion solutions with internal heat recovery (multi-pressure DE) are analysed. The purpose is to identify the highest level of recoverable energy and the optimal design parameters, considering technological constraints such as pressure and minimum end-expansion temperature. The multi-pressure DE solutions prove to be innovative power recovery methods because, with a relatively low use of seawater, it is possible to save regasified LNG and generate electrical power, valorising the energy invested in liquefaction. An estimate of recoverable power in operating terminals is carried out. Configurations with cryogenic or non-cryogenic turboexpanders are discussed. Using the proposed solution with non-cryogenic turboexpander and distribution pressure of 3.5 MPa, 56 kJ for each kg of LNG can be produced, which can become more than 150 kJ/kg with cryogenic turboexpanders. For long-distance distribution, cryogenic multi-pressure DE cycles can recover around 100-120 kJ per kg of LNG. The presented techniques can allow recovery of up to and over 30% of the maximum specific work available in LNG regasification.
2023
Franco, A.; Giovannini, C.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1204849
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact