BACKGROUND: About one-third of candidates for transcatheter aortic valve implantation (TAVI) suffer from severe peripheral artery disease, making the routine femoral approach difficult or impossible. The aim was to compare the transaxillary (TAx) and the transaortic (TAo) route for TAVI with Medtronic CoreValve Revalving System (CRS). METHODS: Out of 1049 consecutive TAVI with 18F CRS, 242 (23%) were treated in 4 high-volume Italian Centre through TAx (61%) and TAo (39%). RESULTS: The devices success was similar (P=0.16) with a trend to a lower incidence of significant paravalvular leak (6% vs. 14%, P=0.07) and a significant reduction of permanent pacemaker (PPM) implantation (13% vs. 34%, P=0.017) in the TAo. However, this route showed a higher incidence of acute kidney injury (P=0.016) and a longer hospital stay after the index procedure (days 10 [8-14] vs. 8 [7-12], P=0.001). By a multivariate analysis the vascular access is an independent predictor for a longer hospital stay (TAo route; OR=0.37, 95% CI: 0.18-0.75; P=0.006) and for PPM implantation (TAx route; OR=3.7, 95% CI: 1.2-10.8; P=0.017). CONCLUSIONS: Although the higher clinical risk profile of transaortic population, the TAo approach showed an equally high device success with similar 30-day safety and 1year efficacy, compared to TAx route. However, due to non-procedure-specific complications post-TAo TAVI, this route requires a specialized postoperative care and the treatment of patients in highly specialized and experienced centers.

Transaxillary versus transaortic approach for transcatheter aortic valve implantation with CoreValve Revalving System: Insights from multicenter experience

De Carlo M.;Scioti G.;Petronio A. S.;
2017-01-01

Abstract

BACKGROUND: About one-third of candidates for transcatheter aortic valve implantation (TAVI) suffer from severe peripheral artery disease, making the routine femoral approach difficult or impossible. The aim was to compare the transaxillary (TAx) and the transaortic (TAo) route for TAVI with Medtronic CoreValve Revalving System (CRS). METHODS: Out of 1049 consecutive TAVI with 18F CRS, 242 (23%) were treated in 4 high-volume Italian Centre through TAx (61%) and TAo (39%). RESULTS: The devices success was similar (P=0.16) with a trend to a lower incidence of significant paravalvular leak (6% vs. 14%, P=0.07) and a significant reduction of permanent pacemaker (PPM) implantation (13% vs. 34%, P=0.017) in the TAo. However, this route showed a higher incidence of acute kidney injury (P=0.016) and a longer hospital stay after the index procedure (days 10 [8-14] vs. 8 [7-12], P=0.001). By a multivariate analysis the vascular access is an independent predictor for a longer hospital stay (TAo route; OR=0.37, 95% CI: 0.18-0.75; P=0.006) and for PPM implantation (TAx route; OR=3.7, 95% CI: 1.2-10.8; P=0.017). CONCLUSIONS: Although the higher clinical risk profile of transaortic population, the TAo approach showed an equally high device success with similar 30-day safety and 1year efficacy, compared to TAx route. However, due to non-procedure-specific complications post-TAo TAVI, this route requires a specialized postoperative care and the treatment of patients in highly specialized and experienced centers.
2017
Fiorina, C.; Bruschi, G.; Testa, L.; De Carlo, M.; De Marco, F.; Coletti, G.; Bonardelli, S.; Adamo, M.; Curello, S.; Scioti, G.; Panisi, P.; Bedogni, F.; Petronio, A. S.; Ettori, F.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1216121
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact