This paper presents the muon momentum calibration and performance studies for the ATLAS detector based on the pp collisions data sample produced at s = 13 TeV at the LHC during Run 2 and corresponding to an integrated luminosity of 139 fb - 1 . An innovative approach is used to correct for potential charge-dependent momentum biases related to the knowledge of the detector geometry, using the Z→ μ+μ- resonance. The muon momentum scale and resolution are measured using samples of J/ ψ→ μ+μ- and Z→ μ+μ- events. A calibration procedure is defined and applied to simulated data to match the performance measured in real data. The calibration is validated using an independent sample of Υ → μ+μ- events. At the Z (J/ ψ) peak, the momentum scale is measured with an uncertainty at the 0.05% (0.1%) level, and the resolution is measured with an uncertainty at the 1.5% (2%) level. The charge-dependent bias is removed with a dedicated in situ correction for momenta up to 450 GeV with a precision better than 0.03 TeV - 1 .

Studies of the muon momentum calibration and performance of the ATLAS detector with pp collisions at √s=13 TeV

Cavasinni V.;Francavilla P.;Roda C.;Verducci M.;
2023-01-01

Abstract

This paper presents the muon momentum calibration and performance studies for the ATLAS detector based on the pp collisions data sample produced at s = 13 TeV at the LHC during Run 2 and corresponding to an integrated luminosity of 139 fb - 1 . An innovative approach is used to correct for potential charge-dependent momentum biases related to the knowledge of the detector geometry, using the Z→ μ+μ- resonance. The muon momentum scale and resolution are measured using samples of J/ ψ→ μ+μ- and Z→ μ+μ- events. A calibration procedure is defined and applied to simulated data to match the performance measured in real data. The calibration is validated using an independent sample of Υ → μ+μ- events. At the Z (J/ ψ) peak, the momentum scale is measured with an uncertainty at the 0.05% (0.1%) level, and the resolution is measured with an uncertainty at the 1.5% (2%) level. The charge-dependent bias is removed with a dedicated in situ correction for momenta up to 450 GeV with a precision better than 0.03 TeV - 1 .
2023
Aad, G.; Abbott, B.; Abeling, K.; Abidi, S. H.; Aboulhorma, A.; Abramowicz, H.; Abreu, H.; Abulaiti, Y.; Abusleme Hoffman, A. C.; Acharya, B. S.; Adam...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1239947
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 4
social impact