Background and objective: The role of pelvic lymph node dissection (PLND) for prostate cancer is still controversial. This study aims to compare the outcomes of PLND between extraperitoneal single-port (SP eRARP) and transperitoneal multi-port (MP tRARP) robotic-assisted radical prostatectomy. Methods: This was a retrospective analysis from our single-center database for patients who underwent SP eRARP or MP tRARP with PLND between 2015 and 2023. The primary endpoint was to analyze and compare specific data related to PLND between the two populations by the detection of pN+ patients, the total num- ber of lymph nodes removed, and the number of positive lymph nodes removed. The secondary endpoints included comparing major complications, lymphoceles, and biochemical recurrence between the two cohorts of the study. Key findings and limitations: A total of 293 patients were included, with 85 (29%) undergoing SP eRARP and 208 (71%) undergoing MP tRARP. SP eRARP showed significant differences in PLND extension from MP tRARP, while MP tRARP yielded more lymph nodes (p < 0.001). There were no differences in pN+ patient detection (p = 0.7) or the number of positive lymph nodes retrieved (p = 0.6). The rates of major complications (p = 0.6), lymphoceles (p = 0.2), and biochemical recurrence (p = 0.9) were similar between the two groups. Additionally, SP eRARP had shorter operative time (p = 0.045), hospital stay (p < 0.001), and less postoperative pain at discharge (p = 0.03). Limitations include a retrospective, single-center analysis. Conclusions and clinical implications: Despite the SP approach in RARP resulting infewer retrieved lymph nodes, outcomes were comparable with the MP approach regarding the detection of patients with positive lymph nodes and the number of positive nodes. Additionally, the SP approach led to lower pain levels and shorter hospital stays. Patient summary: With this study, we demonstrate that pelvic lymph node dissection performed via the extraperitoneal approach during robotic-assisted radical prostatectomy with a single-port system provides comparable outcomes with the standard transperitoneal multiport approach in detecting patients with positive lymph nodes and retrieving positive nodes. In addition, it offers significantly reduced pain levels and shorter hospital stays.

Pelvic Limph node dissection: a comparison among extraperitoneal single-port and trans peritoneal multiport radical prostatectomy- a single center experience

Pacini M;Bartoletti R;
2024-01-01

Abstract

Background and objective: The role of pelvic lymph node dissection (PLND) for prostate cancer is still controversial. This study aims to compare the outcomes of PLND between extraperitoneal single-port (SP eRARP) and transperitoneal multi-port (MP tRARP) robotic-assisted radical prostatectomy. Methods: This was a retrospective analysis from our single-center database for patients who underwent SP eRARP or MP tRARP with PLND between 2015 and 2023. The primary endpoint was to analyze and compare specific data related to PLND between the two populations by the detection of pN+ patients, the total num- ber of lymph nodes removed, and the number of positive lymph nodes removed. The secondary endpoints included comparing major complications, lymphoceles, and biochemical recurrence between the two cohorts of the study. Key findings and limitations: A total of 293 patients were included, with 85 (29%) undergoing SP eRARP and 208 (71%) undergoing MP tRARP. SP eRARP showed significant differences in PLND extension from MP tRARP, while MP tRARP yielded more lymph nodes (p < 0.001). There were no differences in pN+ patient detection (p = 0.7) or the number of positive lymph nodes retrieved (p = 0.6). The rates of major complications (p = 0.6), lymphoceles (p = 0.2), and biochemical recurrence (p = 0.9) were similar between the two groups. Additionally, SP eRARP had shorter operative time (p = 0.045), hospital stay (p < 0.001), and less postoperative pain at discharge (p = 0.03). Limitations include a retrospective, single-center analysis. Conclusions and clinical implications: Despite the SP approach in RARP resulting infewer retrieved lymph nodes, outcomes were comparable with the MP approach regarding the detection of patients with positive lymph nodes and the number of positive nodes. Additionally, the SP approach led to lower pain levels and shorter hospital stays. Patient summary: With this study, we demonstrate that pelvic lymph node dissection performed via the extraperitoneal approach during robotic-assisted radical prostatectomy with a single-port system provides comparable outcomes with the standard transperitoneal multiport approach in detecting patients with positive lymph nodes and retrieving positive nodes. In addition, it offers significantly reduced pain levels and shorter hospital stays.
2024
Pettenuzzo, G; Di Tonno, F; Cannoletta, D; Pacini, M; Morgantini, L; Sauer, Rc; Torres-Anguiano, Jr; Montorsi, F; Briganti, A; Bartoletti, R; Veccia, ...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1259408
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact