: Intra-operative contrast-enhanced ultrasound (CEUS) is a relatively standardized procedure in brain neurosurgery, but it is still underused in spinal cord and intramedullary tumor evaluation. We reviewed and analyzed the intra-operative data from a surgical series of patients harboring intramedullary spinal cord tumors who underwent surgery under CEUS guidance. CEUS was performed in 12 patients (age range: 13-55 y); all lesions had ill-defined boundaries or peritumoral cysts at preliminary intra-operative B-mode ultrasound. CEUS highlighted the tumors in all cases. The contrast agent's spinal distribution revealed different phases (arterial, peak, washout), as observed in the brain, but these appeared to be slower and less intense. In our experience, intra-operative CEUS allows surgeons to assess spinal cord perfusion and highlight intramedullary tumors in real time. As for other imaging modalities, ultrasound contrast agents add valuable information over baseline imaging, and their use should be fostered to better understand microbubble distribution dynamics.

Contrast-Enhanced Ultrasound Assisted Surgery of Intramedullary Spinal Cord Tumors: Analysis of Technical Benefits and Intra-operative Microbubble Distribution Characteristics

Acerbi, Francesco;
2021-01-01

Abstract

: Intra-operative contrast-enhanced ultrasound (CEUS) is a relatively standardized procedure in brain neurosurgery, but it is still underused in spinal cord and intramedullary tumor evaluation. We reviewed and analyzed the intra-operative data from a surgical series of patients harboring intramedullary spinal cord tumors who underwent surgery under CEUS guidance. CEUS was performed in 12 patients (age range: 13-55 y); all lesions had ill-defined boundaries or peritumoral cysts at preliminary intra-operative B-mode ultrasound. CEUS highlighted the tumors in all cases. The contrast agent's spinal distribution revealed different phases (arterial, peak, washout), as observed in the brain, but these appeared to be slower and less intense. In our experience, intra-operative CEUS allows surgeons to assess spinal cord perfusion and highlight intramedullary tumors in real time. As for other imaging modalities, ultrasound contrast agents add valuable information over baseline imaging, and their use should be fostered to better understand microbubble distribution dynamics.
2021
Vetrano, Ignazio G; Gennari, Antonio G; Erbetta, Alessandra; Acerbi, Francesco; Nazzi, Vittoria; Dimeco, Francesco; Prada, Francesco
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1274781
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 8
social impact