Background: The International Anorectal Physiology Working Group (IAPWG) suggests a standardized protocol to perform high-resolution anorectal manometry. The applicability and possible limitations of the IAPWG protocol in performing three-dimensional high-definition anorectal manometry (3D-ARM) have still to be extensively evaluated. Methods: The IAPWG protocol was applied in performing 3D-ARM. Anorectal manometry (ARM) and a balloon expulsion test (BET) were performed according to IAPGW protocol in 290 patients. Key Results: A total of 84 males and 206 females (mean age 57.1 ± 15.7 years) were enrolled in six Italian centers. The reasons for which the patients were sent to perform 3D-ARM were: constipation (53.1%), fecal incontinence (26.9%), anal pain (3.1%), postsurgical (3.8%) and presurgical evaluation (4.8%), prolapse (3.4%), anal fissure (2.8%), and other (2.1%). Due to organic and functional conditions (low rectal anterior resections, rectal prolapses, and J-pouch after colectomy), we were unable to perform a complete 3D-ARM on six patients. Overall, a complete 3D-ARM and BET following IAPWG protocol was carried out in 284 patients (97.9%). The following were recorded: rest pressure (81.9 ± 32.0 mmHg) and length of the anal sphincter (37.0 ± 6.2 cm), maximum anal squeeze pressure (201.6 ± 81.3 mmHg), squeeze duration (22.0 ± 8.8 s), maximum rectal (48.7 ± 41.0 mmHg) and minimum anal pressure (73.3 ± 36.5 mmHg) during push, presence/absence of a dyssynergic pattern, cough reflex and rectal sensations (first constant sensation 48.4 ± 29.5 mL, desire to defecate 83.7 ± 52.1 mL, and maximum tolerated volume 149.5 ± 72.6 mL), and presence/absence of rectoanal inhibitory reflex. Mean 3D-ARM registration time was 14 min 7 s ± 3 min 12 s. Conclusions: This is the first multicentric study that evaluates the applicability of the IAPWG protocol in 3D-ARM performed in different manometric laboratories (both gastroenterological and surgical). The IAPWG protocol was easy to perform and was not time consuming. A diagnosis according to the London Classification was easily obtained in most patients in which 3D-ARM was carried out. No clear limitations to the applicability of the IAPWG protocol were detected.

Feasibility of IAPWG protocol in performing high-definition three-dimensional anorectal manometry: A prospective, multicentric italian study

Lambiase, C.
Writing – Original Draft Preparation
;
Bellini, M.
Ultimo
Writing – Original Draft Preparation
2024-01-01

Abstract

Background: The International Anorectal Physiology Working Group (IAPWG) suggests a standardized protocol to perform high-resolution anorectal manometry. The applicability and possible limitations of the IAPWG protocol in performing three-dimensional high-definition anorectal manometry (3D-ARM) have still to be extensively evaluated. Methods: The IAPWG protocol was applied in performing 3D-ARM. Anorectal manometry (ARM) and a balloon expulsion test (BET) were performed according to IAPGW protocol in 290 patients. Key Results: A total of 84 males and 206 females (mean age 57.1 ± 15.7 years) were enrolled in six Italian centers. The reasons for which the patients were sent to perform 3D-ARM were: constipation (53.1%), fecal incontinence (26.9%), anal pain (3.1%), postsurgical (3.8%) and presurgical evaluation (4.8%), prolapse (3.4%), anal fissure (2.8%), and other (2.1%). Due to organic and functional conditions (low rectal anterior resections, rectal prolapses, and J-pouch after colectomy), we were unable to perform a complete 3D-ARM on six patients. Overall, a complete 3D-ARM and BET following IAPWG protocol was carried out in 284 patients (97.9%). The following were recorded: rest pressure (81.9 ± 32.0 mmHg) and length of the anal sphincter (37.0 ± 6.2 cm), maximum anal squeeze pressure (201.6 ± 81.3 mmHg), squeeze duration (22.0 ± 8.8 s), maximum rectal (48.7 ± 41.0 mmHg) and minimum anal pressure (73.3 ± 36.5 mmHg) during push, presence/absence of a dyssynergic pattern, cough reflex and rectal sensations (first constant sensation 48.4 ± 29.5 mL, desire to defecate 83.7 ± 52.1 mL, and maximum tolerated volume 149.5 ± 72.6 mL), and presence/absence of rectoanal inhibitory reflex. Mean 3D-ARM registration time was 14 min 7 s ± 3 min 12 s. Conclusions: This is the first multicentric study that evaluates the applicability of the IAPWG protocol in 3D-ARM performed in different manometric laboratories (both gastroenterological and surgical). The IAPWG protocol was easy to perform and was not time consuming. A diagnosis according to the London Classification was easily obtained in most patients in which 3D-ARM was carried out. No clear limitations to the applicability of the IAPWG protocol were detected.
2024
Della Casa, D.; Lambiase, C.; Origi, M.; Battaglia, L.; Guaglio, M.; Cataudella, G.; Dell'Era, A.; Bellini, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1287110
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact