The degradation of 2-chlorophenol vapours in air was performed in a trickling biofilter packed with ceramic material seeded with the bacterium Pseudomonas pickettii, strain LD1. The system performance was evaluated under varying operating conditions (inlet 2-chlorophenol air concentrations from 0.10 to 3.50 g m(-3). and superficial air velocities of 30.0, 60.0. and 120.0 m h(-1)). For all air velocity the maximum degradation rate was obtained for loading rates of 40 g m(-2) h(-1). Higher loading conditions resulted in strong inhibition of microbial activity, particularly severe at high air velocity. Process analysis, performed using data on pollutant concentration profiles along the filter packing obtained Under different conditions of inlet concentration and air velocity, proves that best performance (i.e. maximum degradation efficiency and capacity) call be obtained for a narrow range of operating conditions, which call be ensured by proper design of biofilter size (i.e. diameter and height). Kinetic analysis of experimental data confirms that 2-CP inhibits microbial activity in the biofilter bed. Experimental data are satisfactorily fitted by the Haldane kinetic equation up to a critical value of loading rate, beyond which the experimental degradation rate is overestimated by the kinetic model. The inhibition appears to be affected by the loading rate, and the estimated inhibition constant linearly increases with increasing empty bed residence time. (C) 2008 Elsevier B.V. All rights reserved.

Biotrickling air filtration of 2-chlorophenol at high loading rates

NICOLELLA, CRISTIANO;
2009-01-01

Abstract

The degradation of 2-chlorophenol vapours in air was performed in a trickling biofilter packed with ceramic material seeded with the bacterium Pseudomonas pickettii, strain LD1. The system performance was evaluated under varying operating conditions (inlet 2-chlorophenol air concentrations from 0.10 to 3.50 g m(-3). and superficial air velocities of 30.0, 60.0. and 120.0 m h(-1)). For all air velocity the maximum degradation rate was obtained for loading rates of 40 g m(-2) h(-1). Higher loading conditions resulted in strong inhibition of microbial activity, particularly severe at high air velocity. Process analysis, performed using data on pollutant concentration profiles along the filter packing obtained Under different conditions of inlet concentration and air velocity, proves that best performance (i.e. maximum degradation efficiency and capacity) call be obtained for a narrow range of operating conditions, which call be ensured by proper design of biofilter size (i.e. diameter and height). Kinetic analysis of experimental data confirms that 2-CP inhibits microbial activity in the biofilter bed. Experimental data are satisfactorily fitted by the Haldane kinetic equation up to a critical value of loading rate, beyond which the experimental degradation rate is overestimated by the kinetic model. The inhibition appears to be affected by the loading rate, and the estimated inhibition constant linearly increases with increasing empty bed residence time. (C) 2008 Elsevier B.V. All rights reserved.
2009
Nicolella, Cristiano; Converti, A; Zilli, M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/131840
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 12
social impact