In this paper, we present a novel passive dual-tuned magnetic metasurface, which can enhance the field distribution produced by a closely placed radio-frequency coil for both 1H and 23Na 1.5 T MRI imaging. In particular, the proposed solution comprises a 5 × 5 capacitively loaded array, in which each unit-cell is composed of two concentric spiral coils. Specifically, the unit-cell internal spiral coil operates at the proton Larmor frequency (64 MHz), whereas the external is at the sodium one (17 MHz). Therefore, the paper aims to demonstrate the possibility of enhancing the magnetic field distribution in transmission and reception for 1.5 T MRI scanners by using the same metasurface configuration for imaging both nuclei, thus drastically simplifying the required instrumentation. We first describe the theoretical model used to design and synthetize the dual-tuned magnetic metasurface. Next, full-wave simulations are carried out to validate the approach. Finally, we report the experimental results acquired by testing the fabricated prototype at the workbench, observing a good agreement with the theoretical design and the numerical simulations. In particular, the metasurface increases the transmission efficiency Tx in presence of a biological phantom by a factor 3.5 at 17 MHz and by a factor 5 at 64 MHz, respectively. The proposed solution can pave the way for MRI multi-nuclei diagnostic technique with better images quality, simultaneously reducing the scanning time, the invasiveness on the patient and the overall costs.

Dual-Tuned Magnetic Metasurface for Field Enhancement in 1H and 23Na 1.5 T MRI

Lazzoni, Valeria;Dellabate, Alessandro;Brizi, Danilo;Monorchio, Agostino
2025-01-01

Abstract

In this paper, we present a novel passive dual-tuned magnetic metasurface, which can enhance the field distribution produced by a closely placed radio-frequency coil for both 1H and 23Na 1.5 T MRI imaging. In particular, the proposed solution comprises a 5 × 5 capacitively loaded array, in which each unit-cell is composed of two concentric spiral coils. Specifically, the unit-cell internal spiral coil operates at the proton Larmor frequency (64 MHz), whereas the external is at the sodium one (17 MHz). Therefore, the paper aims to demonstrate the possibility of enhancing the magnetic field distribution in transmission and reception for 1.5 T MRI scanners by using the same metasurface configuration for imaging both nuclei, thus drastically simplifying the required instrumentation. We first describe the theoretical model used to design and synthetize the dual-tuned magnetic metasurface. Next, full-wave simulations are carried out to validate the approach. Finally, we report the experimental results acquired by testing the fabricated prototype at the workbench, observing a good agreement with the theoretical design and the numerical simulations. In particular, the metasurface increases the transmission efficiency Tx in presence of a biological phantom by a factor 3.5 at 17 MHz and by a factor 5 at 64 MHz, respectively. The proposed solution can pave the way for MRI multi-nuclei diagnostic technique with better images quality, simultaneously reducing the scanning time, the invasiveness on the patient and the overall costs.
2025
Rotundo, Sabrina; Lazzoni, Valeria; Dellabate, Alessandro; Brizi, Danilo; Monorchio, Agostino
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1332567
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact