The critical current of superconductors is commonly measured by testing unloaded wires under an external magnetic field. While stressed by intense Lorentz forces, the existing HTS/LTS superconductors are prone to a reduction in critical current before reaching their structural mechanical limit. In this work, the magnetic and mechanical analysis of the FNAL 4- layer Bi-2212/Nb3Sn hybrid dipole magnet is reported, aimed at predicting the critical current degradation for both the superconductors during powering at 16 T. All the Rutherford cables in the coils of the hybrid magnet were modeled at the strand level in Ansys APDL with the heterogeneous cable model. Utilizing this detailed geometry, it was possible to evaluate the effects of strain on the critical current degradation for both the Nb3Sn and Bi-2212 superconductors under the intense Lorentz forces. The analysis presented in this paper integrates straindependent critical current laws, with parameters derived from experimental data, to simulate the hybrid magnet’s performance for all possible current-powering configurations. The proposed methodology enables a detailed assessment of conductor integrity and IC (ε) reduction in existing hybrid magnet designs, providing a versatile and rigorous framework for optimizing future highfield hybrid magnets.
A Computational Procedure for Assessing I$_{c}(\varepsilon$) in Nb$_{3}$Sn/Bi-2212 Hybrid Magnets
D'Agliano, A.;Donati, S.;Giusti, V.
2025-01-01
Abstract
The critical current of superconductors is commonly measured by testing unloaded wires under an external magnetic field. While stressed by intense Lorentz forces, the existing HTS/LTS superconductors are prone to a reduction in critical current before reaching their structural mechanical limit. In this work, the magnetic and mechanical analysis of the FNAL 4- layer Bi-2212/Nb3Sn hybrid dipole magnet is reported, aimed at predicting the critical current degradation for both the superconductors during powering at 16 T. All the Rutherford cables in the coils of the hybrid magnet were modeled at the strand level in Ansys APDL with the heterogeneous cable model. Utilizing this detailed geometry, it was possible to evaluate the effects of strain on the critical current degradation for both the Nb3Sn and Bi-2212 superconductors under the intense Lorentz forces. The analysis presented in this paper integrates straindependent critical current laws, with parameters derived from experimental data, to simulate the hybrid magnet’s performance for all possible current-powering configurations. The proposed methodology enables a detailed assessment of conductor integrity and IC (ε) reduction in existing hybrid magnet designs, providing a versatile and rigorous framework for optimizing future highfield hybrid magnets.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.