Containment and surveillance measures for unattended or remotely monitored items and areas serve to detect, timestamp, and thereby deter the illicit movement and trafficking of radioactive material in the interval between two successive inspections. This study explores the feasibility of a passive solution that does not rely on complex electronic components, thus mitigating common vulnerabilities of active instruments, including risks of tampering and unauthorised data access. The signal loss in luminescent materials – dependent on both time and temperature and previously investigated as a means of estimating the time of exposure – proved applicable in this safeguards-relevant context as well. The differential fading of peaks II and III of the glow curve of LiF:Mg,Cu,P (GR-200A), compared to the stable dosimetric peak IV, provided a means to timestamp the moment of irradiation with reasonable accuracy in the short and medium-term after exposure. While the analysis primarily focused on the behaviour of individual crystals, the averaging of multiple responses was also explored for comparison, to assess its potential for reducing estimation error.

Estimation of the time of exposure from the differential fading of luminescent detectors

Roina, Gianpaolo
Primo
;
Nascimento, Debora Siqueira
Secondo
;
Ciolini, Riccardo
Penultimo
;
Quattrocchi, Mariagrazia;d'Errico, Francesco
Ultimo
2025-01-01

Abstract

Containment and surveillance measures for unattended or remotely monitored items and areas serve to detect, timestamp, and thereby deter the illicit movement and trafficking of radioactive material in the interval between two successive inspections. This study explores the feasibility of a passive solution that does not rely on complex electronic components, thus mitigating common vulnerabilities of active instruments, including risks of tampering and unauthorised data access. The signal loss in luminescent materials – dependent on both time and temperature and previously investigated as a means of estimating the time of exposure – proved applicable in this safeguards-relevant context as well. The differential fading of peaks II and III of the glow curve of LiF:Mg,Cu,P (GR-200A), compared to the stable dosimetric peak IV, provided a means to timestamp the moment of irradiation with reasonable accuracy in the short and medium-term after exposure. While the analysis primarily focused on the behaviour of individual crystals, the averaging of multiple responses was also explored for comparison, to assess its potential for reducing estimation error.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/1334547
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact