Aims Transoesophageal echocardiography (TEE) may require patient sedation, eventually leading to respiratory depression, a risky condition in severe cardiac disease. Non-invasive ventilation (NIV) has been applied during diagnostic manoeuvres, but its use during TEE has not been reported. We describe NIV-aided continuous TEE monitoring under sedation in the supine position in three consecutive orthopnoeic patients with severe aortic valve stenosis: two of them underwent percutaneous aortic valve implantation, and one underwent aortic valvuloplasty. Methods and results The TEE probe was passed through a hole performed with a surgical cutter in an NIV face-mask. Pulsoximetry, heart rate, arterial blood pressure, respiratory rate, arterial blood gases, patients’ comfort, and patient’s sedation were monitored throughout the procedure. Percutaneous aortic valve implantation procedures lasted almost 2 h, while the valvuloplasty procedure lasted 70 min. Non-invasive ventilation and continuous TEE were performed throughout the procedures without technical problems or respiratory or haemodynamic complications, and all patients felt always comfortable. Conclusion Non-invasive ventilation through a modified face-mask allowed to perform continuous TEE examination and to avoid tracheal intubation and general anaesthesia in three high-risk patients undergoing beating heart treatment of aortic valve stenosis. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Non-invasive ventilation-aided transoesophageal echocardiography in high-risk patients: a pilot study

PETRONIO, ANNA;
2010-01-01

Abstract

Aims Transoesophageal echocardiography (TEE) may require patient sedation, eventually leading to respiratory depression, a risky condition in severe cardiac disease. Non-invasive ventilation (NIV) has been applied during diagnostic manoeuvres, but its use during TEE has not been reported. We describe NIV-aided continuous TEE monitoring under sedation in the supine position in three consecutive orthopnoeic patients with severe aortic valve stenosis: two of them underwent percutaneous aortic valve implantation, and one underwent aortic valvuloplasty. Methods and results The TEE probe was passed through a hole performed with a surgical cutter in an NIV face-mask. Pulsoximetry, heart rate, arterial blood pressure, respiratory rate, arterial blood gases, patients’ comfort, and patient’s sedation were monitored throughout the procedure. Percutaneous aortic valve implantation procedures lasted almost 2 h, while the valvuloplasty procedure lasted 70 min. Non-invasive ventilation and continuous TEE were performed throughout the procedures without technical problems or respiratory or haemodynamic complications, and all patients felt always comfortable. Conclusion Non-invasive ventilation through a modified face-mask allowed to perform continuous TEE examination and to avoid tracheal intubation and general anaesthesia in three high-risk patients undergoing beating heart treatment of aortic valve stenosis. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2010
Guarracino, F; Cabrini, L; Baldassarri, R; Cariello, C; Covello, Rd; Landoni, G; Petronio, Anna; Petronio, A.
File in questo prodotto:
File Dimensione Formato  
Non-invasive ventilation-aided transoesophageal echocardiography in high-risk patients a pilot study.pdf

solo utenti autorizzati

Tipologia: Versione finale editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 103.94 kB
Formato Adobe PDF
103.94 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11568/136326
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 47
  • ???jsp.display-item.citation.isi??? ND
social impact